B&B Electronics MES1A Manual

B&B Electronics MES1A Manual

Modbus tcp to modbus ascii / rtu converters
Hide thumbs Also See for MES1A:
Table of Contents

Advertisement

Quick Links

M
o
M
o
M
M
M
o
d
M
o
d
Manual Documentation Number: MES1A/MES1B-2106m
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
d
e
l
s
:
M
E
S
1
A
,
M
E
d
e
l
s
:
M
E
S
1
A
,
M
E
o
d
b
u
s
T
C
o
d
b
u
s
T
C
t
o
t
o
b
u
s
A
S
C
I
I
b
u
s
A
S
C
I
I
C
o
n
v
e
r
t
e
r
s
C
o
n
v
e
r
t
e
r
s
S
1
B
S
1
B
P
P
/
R
T
U
/
R
T
U
PN7138-rev001

Advertisement

Table of Contents
loading

Summary of Contents for B&B Electronics MES1A

  • Page 1 Manual Documentation Number: MES1A/MES1B-2106m B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com...
  • Page 2 Manual Documentation Number: MES1A/MES1B-2106m PN7138-rev001 B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com...
  • Page 3 Technical Support e-mail: support@bb-europe.com © B&B Electronics – May 2006 Manual Documentation Number: MES1A/MES1B-2106m PN7138-rev001 B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com...
  • Page 5 All brand names used in this manual are the registered trademarks of their respective owners. The use of trademarks or other designations in this publication is for reference purposes only and does not constitute an endorsement by the trademark holder. Manual Documentation Number: MES1A/MES1B-2106m PN7138-rev001 B&B Electronics Mfg Co Inc –...
  • Page 7: Table Of Contents

    CHAPTER 3: GETTING STARTED ... 11 ... 11 UICK TART Check the contents of your MES1A/B package. It should contain…... 11 Set up the Hardware ... 11 Software Installation ... 11 Discover the MES1A/B on the Network ... 12 Configure the MES1A/B... 12 Modbus Device Installation ...
  • Page 8 CHAPTER 4: CONFIGURING THE MES1A/B... 19 AVIGATING THE ONFIGURATION 1) N /IP S ... 22 ETWORK ETTINGS IP Address... 22 Default Gateway ... 23 Netmask... 24 Telnet Configuration Password ... 24 2) S ... 24 ERIAL AND ETTINGS Protocol ... 25 Serial Interface...
  • Page 9 APPENDIX D: SERIAL CONNECTIONS ... 57 APPENDIX E: NETWORK CONNECTIONS ... 59 Manual Documentation Number: MES1A/MES1B-2106m B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics Ltd –...
  • Page 10 Manual Documentation Number: MES1A/MES1B-2106m PN7138-rev001 B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com...
  • Page 11: Chapter 1: Introduction

    About this Manual This manual has been created to assist you in installing, configuring and using the MES1A/B. Please read it carefully and follow the instructions to achieve best results. Support For additional information on this and other B&B products, and for technical support, call 815.433.5100 option 3, or access B&B Electronics’...
  • Page 12: Features

    Traditional Modbus ASCII/RTU master devices also can be connected to TCP/IP networks using the MES1A/B, making the device appear to be a full Modbus TCP master on the network. It can directly access Modbus TCP slave devices. It also can access other Modbus ASCII/RTU slaves that are connected to the network via other MES1A/B Converters, as if it is talking directly to a Modbus ASCII/RTU slave.
  • Page 13: Chapter 2: Hardware Overview

    MES1A/B Modbus ASCII/RTU to Modbus TCP Converters are shipped with the following items included: the MES1A or MES1B module a printed version of this user manual a printed version of the MES1A/B Quick Start Guide a CD-ROM disc with Device Installer software this manual in pdf format...
  • Page 14: Link Led

    Orange Figure 3. Reset Switch The Reset switch is accessible on the top edge of the MES1A/B (same edge as the power supply connector) through a small hole in the MES1A/B enclosure. It allows you to reset the MES1A/B by inserting a small tool through the hole and pressing the momentary switch for about 1 second.
  • Page 15: Ethernet Port Connector

    LEDs (described above) are built into the RJ-45 connector. DB-9M Serial Port Connector (MES1A only) The Serial Port Connector on the MES1A is a DB-9 male connector (configured as a DTE) supporting RS-232 serial communications including TD (Pin 3), RD (Pin 2) and GND (Pin 5) signal lines.
  • Page 16 TDB and TDA. The communications cable ground/shield is connected to GND. Manual Documentation Number: MES1A/MES1B-2106m B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics Ltd –...
  • Page 17: Power Connector

    MES1A/B Power Connector Connecting the Hardware The MES1A is connected to its Modbus device via a DB-9M connector and an RS-232 cable. The MES1A is configured as a DTE. If the connected Modbus device is configured as a DCE, use a Manual Documentation Number: MES1A/MES1B-2106m B&B Electronics Mfg Co Inc –...
  • Page 18 Power is supplied to the converter via the power supply terminal block. Typically, the MES1A/B is connected to the network via a hub switch or router using standard straight-through CAT-5 cable. (If you are connecting the MES1A/B directly to a PC’s network interface a crossover Ethernet cable is required.)
  • Page 19 Hardware Overview Figure 9. MES1B Connections Manual Documentation Number: MES1A/MES1B-2106m PN7138-rev001 B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-...
  • Page 20 Hardware Overview Manual Documentation Number: MES1A/MES1B-2106m PN7138-rev001 B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com...
  • Page 21: Chapter 3: Getting Started

    2. Set up the Hardware Connect the MES1A/B to the network using an Ethernet cable. Connect your PC to the network Connect a 12 VDC power supply (not included) to the MES1A/B and apply power. (10 to 30 VDC, 3.6 Watts.) 3. Software Installation Insert the software CD and it should auto-start into the installation wizard.
  • Page 22: Discover The Mes1A/B On The Network

    Connect the Modbus device to the serial interface on the MES1A/B using the correct cabling: MES1A is a DTE: Use a straight through serial cable if the Modbus device is a DCE; null modem if device is DTE. MES1B: Four-wire for RS-422, Two-wire for RS-485, Set RS-422/485 switch.
  • Page 23: Using The Device Installer Software

    This section provides more detailed information on how to install and use the Device Installer software. Device Installer is used to set up and configure the MES1A/B on a network. It detects all MES1A/Bs on the network and allows you to configure the network and serial port settings.
  • Page 24: Starting The Device Installer

    • Press the F5 function key When discovered for the first time, any MES1A/B devices present are listed in the Devices Tree pane and Device List pane as XPort and XPort IAP respectively. (XPort is the name of the internal module of the MES1A/B.)
  • Page 25: Getting Device Details

    Figure 11. Device Details Tab Note: The Web Configuration tab is not used with the MES1A/B. Manual Documentation Number: MES1A/MES1B-2106m B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics Ltd –...
  • Page 26: Connecting To The Mes1A/B

    Connecting to the MES1A/B Before configuration can occur you must set up a telnet connection with the MES1A/B to access the Configuration Menu. You can access the Configuration Menu using a standard telnet window, or use the telnet implementation within the Device Installer software.
  • Page 27: Getting Started

    Telnet Configuration Tab with Settings Refer to Chapter 4 for configuration details. Manual Documentation Number: MES1A/MES1B-2106m PN7138-rev001 B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics Ltd –...
  • Page 28 Getting Started Manual Documentation Number: MES1A/MES1B-2106m PN7138-rev001 B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com...
  • Page 29: Chapter 4: Configuring The Mes1A/B

    Configuration of the MES1A/B is accomplished from the Configuration Menu, which is accessed via a standard telnet window, or through the telnet implementation within the Device Installer software. Note: The Web Configuration tab is not used with the MES1A/B. Figure 14. Manual Documentation Number: MES1A/MES1B-2106m B&B Electronics Mfg Co Inc –...
  • Page 30: Navigating The Configuration Menu

    7. Serial & Mode Settings 8. Modem/Configurable Pin Settings 9. Advanced Modbus Protocol Settings The following menu item 5) appears if the MES1A/B is configured as a Modbus Master in section 2) Serial Protocol 10. Unit ID to IP Address Table Each section of the configuration menu includes several parameters.
  • Page 31: To Reconfigure The Mes1A To Factory Settings

    Command or parameter set (1..4) to change: Quitting Without Saving To Quit the configuration session without saving, type Q. The background color will change to gray and the MES1A/B will re-start without updating the configuration settings. Reconfiguring to Factory Settings The MES1A and MES1B come from the factory preconfigured for correct operation with their respective interfaces.
  • Page 32: Network/Ip Settings

    Configuration Protocol) from a DHCP server on the network when the MES1A/B boots up. If a DHCP server is available to respond to the DHCP request, the MES1A/B will receive an IP address, gateway address and subnet mask from the server.
  • Page 33: Default Gateway

    Auto-IP If a DHCP server is NOT available on the network, the MES1A/B will revert to Auto-IP and generate its own IP address in the 169.254.xxx.xxx range. Static IP Address The IP address of the MES1A/B can be changed via the Telnet Configuration Menu interface.
  • Page 34: Netmask

    MES1A/B, the new settings will appear in the Device Details tab. Netmask Typically you will type N, or just press Enter to cause the MES1A/B to automatically use the standard Netmask appropriate for the IP address being used. The default value for this parameter is To change the Netmask setting 20.
  • Page 35: Protocol

    Protocol Protocol parameters must be set to match the type of Modbus device (master or slave) connected to the serial side of the MES1A/B device, and the type of Modbus protocol (ASCII or RTU) that will be used. Attached Device Modbus devices operate as either Masters (polling Slaves) or Slaves (responding to polls from Masters).
  • Page 36: Serial Interface

    Configuring the MES1A/B The MES1A/B must be configured to use the same protocol used by the attached Modbus device. To configure the type of Serial Protocol 27. At the Serial Protocol (1=Modbus/RTU 2=Modbus/ASCII) prompt To keep the current setting, press Enter...
  • Page 37: Modem/Configurable Pin Settings

    No jumpers are required to bridge transmit and receive lines on the terminal block Serial Parameters MES1A/B Serial Parameters must be set up to match the parameters of the Modbus device connected to its serial interface. MES1A/B Serial Parameter options include: •...
  • Page 38: Advanced Modbus Protocol Settings

    MES1B for RS-485 two-wire operation, the CP1 parameter must be set for RS485 Enable to ensure Send Data Control is implemented. No configuration is required in this section for MES1A converters. To configure RS485 Enable in the Modem/Configurable Pin Settings section: 33.
  • Page 39: Slave Address / Unit Id Source

    0 for Auto Setting the Slave Address field to 0 allows the MES1A/B to use the Unit ID received from a Modbus master to direct messages to a specific slave address. The MES1A/B receives the Unit ID number on the Modbus/TCP side and passes it along as the Slave Address on the serial side of the converter.
  • Page 40: Allow Modbus Broadcasts

    If any Modbus TCP masters on your system use 0 for all Unit ID fields, select a slave address that matches the Modbus/RTU slave attached to your MES1A/B. You will not be able to connect multiple slaves to the RS-485 multidrop bus.
  • Page 41: Disable Modbus/Tcp Pipeline

    • Setting this field to 2 = Yes configures the MES1A/B to always fetch the latest request from the TCP buffer (discarding all older requests). Character Timeout Although Modbus/RTU specifies a 3.5 character time out period between characters, the Character Timeout field allows you to set a custom value for this field.
  • Page 42: Serial Tx Delay After Rx

    Configuring the MES1A/B Serial TX Delay after RX When the MES1A/B receives a request from a master it relays the request to the Modbus slave connected to the MES1A/B’s serial connection. When the slave responds a timer is triggered and, after the delay time configured in the Serial TX Delay after TX field, the next master request is allowed to pass through the serial connection to the slave.
  • Page 43: Redundant Entry Retries After

    When you press appears. Manual Documentation Number: MES1A/MES1B-2106m B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com...
  • Page 44: Slave Ip Address

    Type in the four octets of the IP address of the slaves being addressed. • If you configure the last octet as 000 the MES1A/B will use the Slave Address/Unit ID of the slave as part of the IP address. This allows a Modbus/RTU master (connected through the MES1A/B) to access up to 255 remote Modbus TCP slaves.
  • Page 45: Chapter 5: Using Other Device Installer Features

    This section provides a brief overview of those features. For more information, access the Help files from the main menu. Device Installer features which are not used or supported by the MES1A/B include: •...
  • Page 46: Saving Device Lists

    Open. The MES1A/B will search for all devices listed in the Device List file and display them in the Devices Tree. Devices not listed in the Device List file will not be shown.
  • Page 47: Adding A Device Manually

    Figure 22. Adding a Device Manually Although you will typically discover MES1A/B devices on the network using the Search tool, you can also add a device to the network manually. To do so you must know the IP address of the device.
  • Page 48: Assigning An Ip Address (Using Device Installer)

    Therefore, do not use the Obtain an IP address automatically option in the wizard. 44. If you wish to assign a different IP address to the MES1A/B, select Assign a specific IP address and click Next. The IP Settings page of the wizard appears.
  • Page 49: Using The Devices Details Tab

    49. The new IP address appears in the Devices Tree, Device Details tab and Telnet Configuration tab. Using the Devices Details Tab The Device Details tab provides useful information about the MES1A/B currently selected in the Device List. Figure 24.
  • Page 50: Upgrading Firmware

    Adding Info to the Device Details Tab Upgrading Firmware From time to time updated firmware versions for the MES1A/B may become available (from the B&B Electronics website). Device Installer provides a Device Upgrade Wizard which can be used to install updated firmware into the MES1A/B.
  • Page 51: Installing Pre-Saved Configuration Files

    Installing Pre-Saved Configuration Files The same wizard can be used to install previously saved configuration settings (Setup Records) into the MES1A/B. This can be useful if you want to configure multiple MES1A/Bs with the same settings, or if you must replace an MES1A/B and want to load identical settings into the new unit.
  • Page 52: Installing Setup Records

    58. Create a filename and click Save. Installing Setup Records To install a Setup Record in the MES1A/B: 59. On the Device menu, select Upgrade…, or click the Upgrade icon. The Device Upgrade Wizard – Step 1 of 5 dialog box appears.
  • Page 53: Logging Search And Upgrade Data

    64. To enable logging select Options… on the Tools menu. The Options dialog box opens. Manual Documentation Number: MES1A/MES1B-2106m B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics Ltd –...
  • Page 54 Figure 32. Manual Documentation Number: MES1A/MES1B-2106m B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com...
  • Page 55: Using Ping

    Figure 34. Manual Documentation Number: MES1A/MES1B-2106m B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com...
  • Page 56 Using Other Device Installer Features Manual Documentation Number: MES1A/MES1B-2106m PN7138-rev001 B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com...
  • Page 57: Chapter 6: Modbus Basics

    More commonly the master polls individual slaves sequentially. In each poll Manual Documentation Number: MES1A/MES1B-2106m B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics Ltd –...
  • Page 58: Modbus/Tcp

    Manual Documentation Number: MES1A/MES1B-2106m PN7138-rev001 B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com...
  • Page 59: Hints And Tips

    IP address and always used a Unit ID of 00. If this early equipment is used, only one Modbus/RTU slave can be connected to an MES1A/B. (The MES1B is capable of RS-485 multidrop, allowing multiple slaves.)
  • Page 60 Modbus Basics Manual Documentation Number: MES1A/MES1B-2106m PN7138-rev001 B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com...
  • Page 61: Appendix A: Default Configuration Settings

    Serial TX delay after RX: 0 milliseconds Swap 4x/0H to get 3x/1x: No Manual Documentation Number: MES1A/MES1B-2106m B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics Ltd –...
  • Page 62 Default Configuration Settings Manual Documentation Number: MES1A/MES1B-2106m PN7138-rev001 B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com...
  • Page 63: Appendix B: Product Specifications

    Operating Systems supported Windows 98/ME/2000/XP/NT 4.0 (call B&B Tech Support for other operating systems) Dimensions MES1A/MES1B – 1.25 x 4.5 x 4.75 in (3.2 x 11.3 x 12.2 cm) Power Supply Requirements: 10 VDC to 30VDC (3.6 Watts) Power Supply:...
  • Page 64 Product Specifications Interface Lines Supported: MES1A – RS-232 TD, RD, GND MES1B – RS-422/485 TDA(-), TDB(+), RDA(-), RDB(+), GND Serial Data Rates: 300, 600, 1200, 2400, 3600, 4800, 9600, 19200, 38400, 57600, 115200 Parity: None, Even, Odd Data Bits: 7 or 8...
  • Page 65: Appendix C: Dimensional Diagrams

    Dimensional Diagrams Figure 35. Dimensional Diagram of the MES1A Manual Documentation Number: MES1A/MES1B-2106m PN7138-rev001 B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com...
  • Page 66 Dimensional Diagrams Figure 36. Dimensional Diagram of the MES1B Manual Documentation Number: MES1A/MES1B-2106m PN7138-rev001 B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com...
  • Page 67: Appendix D: Serial Connections

    Figure 38. MES1B Terminal Block Pin-out for RS-422/485 Four-Wire Manual Documentation Number: MES1A/MES1B-2106m B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com...
  • Page 68 Figure 39. MES1B Terminal Block Pin-out for RS-485 Two-Wire Manual Documentation Number: MES1A/MES1B-2106m B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com...
  • Page 69: Appendix E: Network Connections

    Figure 40. Pin-out for a Standard Ethernet Cable Manual Documentation Number: MES1A/MES1B-2106m B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com...
  • Page 70 Network Connections Manual Documentation Number: MES1A/MES1B-2106m PN7138-rev001 B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com...
  • Page 71: Declaration Of Conformity

    DECLARATION OF CONFORMITY Manufacturer’s Name: B&B Electronics Manufacturing Company Manufacturer’s Address: 707 Dayton Road Ottawa, IL 61350 USA Model Numbers: ESR901WB Description: Type: Light industrial ITE equipment Application of Council Directive: Standards: EN 55022 EN 61000-6-1 EN 61000 (-4-2, -4-3, -4-4, -4-5, -4-6, -4-8, -4-11) Michael J.