Quick Start Guide
Modbus TCP to
Modbus ASCII/RTU
Converters
Models: MES1A/MES1B
MES1A
MES1B
RS-232 Model
RS-422/485 Model
Documentation Number MES1A/B-2106qsg
1
C
C
h
h
e
e
c
c
k
k
P
P
MES1A or MES1B unit
Printed version of this MES1A/B Quick Start Guide
Printed manual
Software CD
2
H
a
r
d
w
a
H
a
r
d
w
a
Connect the MES1A/B to the network using an Ethernet
cable.
Connect your PC to the network.
Connect a 12 VDC power supply (not included) to the
MES1A/B and apply power. (10 – 30VDC, 3.6 Watts)
3
S
o
f
t
w
a
r
S
o
f
t
w
a
r
Insert the software CD. It should auto-start into the
installation wizard.
Follow the on screen installation wizard to install the
Device Installer software.
Software supports Windows 98, Me, 2K, XP, & NT 4.0
4
D
D
i
i
s
s
c
c
o
o
v
v
e
e
Open the Device Installer software. It should detect the
MES1A/B and display XPort in the third level of the
Devices Tree.
Expand the tree and click the device IP Address.
Select the Telnet Configuration tab, then click Connect.
Press Enter within five seconds to go into Setup Mode.
PN7137-rev001
a
a
c
c
k
k
a
a
g
g
e
e
C
C
o
o
n
n
t
t
e
e
n
n
t
t
r
e
I
n
s
t
a
l
l
a
t
i
o
n
r
e
I
n
s
t
a
l
l
a
t
i
o
n
e
I
n
s
t
a
l
l
a
t
i
o
n
e
I
n
s
t
a
l
l
a
t
i
o
n
r
r
t
t
h
h
e
e
M
M
E
E
S
S
1
1
A
A
/
/
B
B
o
o
n
n
t
t
h
h
e
e
n
n
e
e
t
t
w
w
o
o
International Headquarters: 707 Dayton Road PO Box 1040 Ottawa, IL 61350 USA
815-433-5100 Fax 433-5104
European Headquarters: Westlink Commercial Park Oranmore Co. Galway Ireland
+353 91 792444 Fax +353 91 792445 www.bb-europe.com orders@bb-europe.com support@bb-europe.com
Documentation Number MES1A/B-2106qsg
5
C
C
o
o
n
n
f
f
i
i
g
g
u
u
r
r
e
e
t
t
h
h
e
e
M
M
To change the IP Address, Default Gateway or Netmask, type 1.
To configure Master/Slave and Serial Interface settings, type 2.
Do not change any configuration settings in section 3.
To configure Modbus/TCP Settings, type 4.
To configure Modbus Master settings, type 5.
To save your settings in the MES1A/B, type S.
6
M
M
o
o
d
d
b
b
u
u
s
s
D
D
e
e
v
v
i
i
c
c
e
e
Connect Modbus device to the serial interface on the
MES1A/B using the correct cabling:
-
MES1A is a DTE: Use a straight through serial cable if
the Modbus device is a DCE; null modem if device is DTE
-
MES1B: Four-wire for RS-422, two-wire for RS-485, Set
RS-422/485 switch.
Your Modbus device should now be operational on the
network.
7
L
E
D
S
t
a
t
u
s
L
E
D
S
t
a
t
u
s
LED
Color/Status
Power
Link
r
r
k
k
Activity
Green (Blinking)
Note: The MES1A/B can be reset (rebooted) by pressing the Reset
switch for one second. Reset switch is accessed through a small hole in
the top of the enclosure.
Warning: Do not forget your password if used. There is no easy way to
get into the unit for configuration once you forget your password.
www.bb-elec.com
orders@bb-elec.com support@bb-elec.com
PN7137-rev001
E
E
S
S
1
1
A
A
/
/
B
B
I
I
n
n
s
s
t
t
a
a
l
l
l
l
a
a
t
t
i
i
o
o
n
n
Function
Red
Power applied
Orange
Bootup, 10BaseT
Green
100BaseT
Data on the network
Orange
Bootup