The present service instruction contains a technical description, technical data sheets, operation and mounting guidelines, safety precautions and warnings for safe and correct operation of the fans BLAUBERG Lux and Glory. The fan is designed for exhaust ventilation of residential and public premises heated during winter season.
BASIC CHARACTERISTICS The fan designations, delivery set options, parameters, outer view, overall and connecting dimensions are shown in tables 1, 2, 3 and in fig. 1 and 2. The model without timer is shown in fig. 1. Table 1 Noise level, Max.
OPERATION RULES The fan is rated for connection to 220...240 V / 50 Hz power mains and is designed for continuous operation always connected to power mains. The air motion direction in the system must match the pointer on the fan casing.
Page 6
The product is not allowed for use by children and persons with reduced physical, mental or sensory capacities, without proper practical experience or expertise, unless they are controlled or instructed on the product operation by the person(s) responsible for their safety. Supervise the children and do not let them play with the product.
MOUNTING AND SETUP The fan is designed for wall mounting to extract air into a ventilation shaft or matching air duct of respective diameter (fig. 3-5). The fan mounting sequence is shown in fig. 6. The fan wiring diagrams are shown in fig.7-10. Fig.
Page 9
WIRING DIAGRAMS AND FAN OPERATION LOGIC LUX/GLORY 100/125/150 Fig. 7 Fan does not run Light is off Switch is closed Fan runs Light is on S - external switch QF - automatic switch Fig. 8 Fan does not run S1/S2 S1/S2 Light is off Switch S2 is closed,...
Page 10
Fig. 9 LUX/GLORY 100 T 2min 30min S - external switch QF - automatic switch Fan does not run Light is off Switch is closed Fan runs Light is on Switch is opened Turn-off delay timer starts (2 to 30 min)
Page 11
Fig. 10 LUX/GLORY 100 H 2min 30min S - external switch QF - automatic switch Fan does not run Light is off Switch is closed Humidity exceeds set point Fan runs Light is on Fan runs Light is on Switch is opened Humidity is below set point...
Page 12
WARNING! The timer circuit is under mains voltage! Disconnect the fan from power mains prior to any adjustment operations. The fan delivery set includes a specially designed plastic screwdriver for fan settings adjustments. Use the screwdriver to adjust the turn-off delay time or the humidity threshold.
MAINTENANCE Any servicing and maintenance operations of the fan are allowed after it is disconnected from power mains only. Maintenance means regular cleaning of the fan surfaces from dirt and dust. To clean the fan, wipe its surfaces with a cloth wetted in a mild soap solution, then wipe the surfaces dry.
MANUFACTURER'S WARRANTY The fan complies with the requirements according to the EU norms and directives, to the relevant EU-Low Voltage Equipment Directives, EU-Directives on Electromagnetic Compatibility. We hereby declare that the following product complies with the essential protection requirements of Electromagnetic Council Directive 2004/108/EC, 89/336/EEC and Low Voltage Directive 2006/95/EC, 73/23/EEC and CE-marking Directive 93/68/EEC on the approximation of the laws of the Member States relating to electromagnetic compatibility.