Summary of Contents for BLAUBERG Calm

  • Page 1 Calm Service Instructions...
  • Page 2: Complete Set

    The present operation manual contains a technical description, technical data sheets, operation and mounting guidelines, safety precautions and warnings for safe and correct operation of the fan BLAUBERG Sileo. BLAUBERG Sileo fan is designed for ventilation of residential and public premises heated during winter season and is constructed for wall or ceiling mounting, fig.
  • Page 3: Basic Characteristics

    Switch — integrated pull cord switch. Timer — turn-on delay timer adjustable from 0 up to 2 minutes (only Calm 150 and Calm Max 150 models) and turn-off delay timer adjustable from 2 up to 30 minutes. Humidity sensor — humidity control with set point from 60% up to 90%.
  • Page 4: Operation Rules

    Dimensions [mm] Model Calm 100 Calm 125 Calm 150 Calm Max 150 Fig. 1 OPERATION RULES The fan is rated for connection to 220...240 V / 50 Hz power mains and is designed for continuous operation always connected to power mains.
  • Page 5: Safety Rules

    SAFETY RULES All operations related to the fan electrical connections, servicing and repair works are allowed only after the fan disconnection from power mains. All mounting and servicing operations are allowed for duly qualified electricians with valid electrical work permit for electric operations at the units up to 1000 V after careful study of the present user's manual.
  • Page 6: Mounting And Setup

    MOUNTING AND SETUP The fan is designed for ceiling or wall mounting and installation into a ventilation shaft or connection to a round air duct of respective diameter, fig. 2-4. The fan mounting sequence is shown in fig. 5-13. The wiring diagrams are shown in fig. 14-25. Fig.
  • Page 7 Fig. 5 Fig. 6 Fig. 7 Fig. 8 Fig. 9...
  • Page 8 Fig. 10 Fig. 11 Fig. 12 Fig. 13...
  • Page 9: Wiring Diagrams

    WIRING DIAGRAMS Fig. 14 Calm 100/125 Calm100/125 S Fig. 15 Calm 100/125 ST Calm 100/125 SH Calm 100/125 IR Calm100/125 T Fig. 16 Calm 100/125 H Fig. 17 Calm 150 Calm MAX 150 first speed...
  • Page 10 Calm MAX 150 second speed Calm 150 Fig. 19 Calm MAX 150 first and second speed CDP-2/5 speed CDP-2/5 speed Calm150 S Fig. 20 Calm MAX 150 S first speed Calm 150 S Fig. 21 Calm MAX 150 S second speed...
  • Page 11 Fig. 22 Calm 150 S first and second speed Calm MAX 150 S speed Calm 150 T Fig. 23 Calm MAX 150 T Calm 150 H Calm MAX 150 H Fig. 24 Calm 150 ST Calm MAX 150 ST SILEO 150 SH...
  • Page 12 Calm Max 150 models). Do not use a metal screwdriver, knife, etc. for adjustment operations not to damage the circuit board. Fig. 26 Calm 100/125 Calm 150/Calm Max 150 0 min 2 min 2 min 30 min 2 min 30 min...
  • Page 13: Fan Speed Selection

    The Calm 100 and Calm 125 models are the single-speed fans. The Calm 150 and Calm Max 150 models are the two-speed fans. The required speed for the basic models Calm 150 and Calm Max 150 as well as S model modifications is set during connection to power mains.
  • Page 14 The light indicator glows yellow during operation of all the Calm 100, Calm 125 models as well as Calm 150, Calm Max 150 basic and S models. The light indicators glows as shown in fig. 27 during operation of the fan models Calm 150 and Calm Max150 T/ST/H/SH/IR.
  • Page 15 FAN OPERATION LOGIC Turn-on delay timer - in case of the switch closing or activation of the humidity or motion sensor the timer countdown from 0 up to 2 minutes is activated. Within this time the fan remains in the previous operation mode.
  • Page 16: Maintenance

    MAINTENANCE Disconnect the fan from power mains prior to any servicing and maintenance operations. Maintenance means regular cleaning of the fan surfaces of dirt and dust. To clean the fan, wipe its surfaces with a cloth wetted in a mild soap solution, then wipe the surfaces dry, fig.
  • Page 17: Storage And Transportation Rules

    Fig. 31 Fig. 32 Fig. 33 STORAGE AND TRANSPORTATION RULES Transportation is allowed by any transportation vehicle provided that the product is in the manufacturer's original package. Store the delivered product in the manufacturer's original packing box in a dry ventilated premise with the ambient temperature from +5°C up to + 40°C and relative humidity less than 80%.
  • Page 18: Manufacturer's Warranty

    Protection degree index according to IP rating against access to hazardous parts and water ingress is IP 45 for Calm 100, Calm 125, Calm 150 and IP X5 for Calm Max 150 model. The fan is double insulated and does not require grounding.
  • Page 19 ACCEPTANCE CERTIFICATE...
  • Page 20 Calm Calm Max Fan is recognized as serviceable. SALES DATE SOLD MANUFACTURED ON (DATE): APPROVAL MARK Calm_EN-07...