Install DIMM Memory Modules
DDR3 DIMM Memory Identification:
Memory Configurations and Population Order:
Minimum of one 1 GB DDR3-800/1066/1333 RDIMM or UDIMM.
The Intel
®
Workstation Board S5520SC
Install from first slot of each channel (A1, B1, C1, D1, E1, or F1).
supports up to 12 DDR3-800/1066/1333
Install Quad-Rank DIMM from first slot of each channel.
RDIMMS orUDIMMS.
Channel D, E, and F are not available when CPU 2 socket is empty.
Mixing of RDIMMs and UDIMMs is not
Mixing memory type, size, speed and/or rank on this platform has not been
supported.
validated and is not supported.
Mixing memory vendors is not supported on this platform by Intel
Non-ECC memory is not supported and has not been validated in a
server environment.
DIMM notch and
socket bump must
align as shown.
DDR3
10
Install (Optional) RAID 5 Activation
Key/Connect (Optional) SGPIO Cable/
Connect Hard Drives/Optical Drive
to Workstation Board
A
(Optional) Install optional RAID 5 activation
Workstation
key (AXXRAKSW5) on on-board RAID 5
Board
key connector as shown.
B
(Optional) Connect the SGPIO cable to the
5
workstation board SGPIO connector as
shown. Connect the other end of the SGPIO
4
cable to the hot-swap hard disk backplane
A
RAID 5 Key
3
if installed.
C
Connect SATA data cables
B
2
SGPIO
C
to the workstation board as
1
shown.
0
Begin cable connections
SATA Data
at the SATA 0 location.
Cable Connector
15
Chassis Fan
Connections
See the documentation accompanying your
chassis for specific chassis fan connection
requirements. For a non-Intel server chassis,
see "Making Connections ... Quick Reference"
below and see the Intel
®
Workstation Board
S5520SC Service Guide.
CPU 1 Socket
Attach system
fans with
3, 4, or 6-pin
connectors here.
CPU 2 Socket
Making Connections
Required
Connections
to the Workstation
CPU 1 Power Connector
CPU 2 Power Connector
Board
Main Power Connector
Auxiliary Power Connector
Quick Reference
Front Panel Connector
CPU/System Fan
Connections
CPU Fan 1 Connector
CPU Fan 2 Connector
Chassis Fan 1 Connector
Chassis Fan 2 Connector
IMPORTANT Note:
Chassis Fan 3 Connector
Cables should be tied
Chassis Fan 4 Connector
for better airflow.
Use cable-ties as necessary.
Chassis Fan 5 Connector
Optional
Connections
HSBP_A
Note: Not all optional
HSBP_B
connections are shown in this
USB_Front Panel
diagram. Refer to the Reference
SATA Connectors
section of this Quick Start User's
SATA Software RAID 5 Key
Guide, your Intel
®
Workstation Board
SAS Module SAS Connectors (optional)
S5520SC Service Guide, and your
Serial B
server chassis documentation for
SATA SGPIO
additional connection information.
SAS Module SES (optional)
SAS Module SGPIO (optional)
SAS Software RAID 5 Key (optional)
Note: For a non-Intel chassis, see your chassis documentation for workstation board connection information.
To Install DIMMs:
CAUTION: Avoid touching contacts
when handling or installing DIMMs.
A
Open both DIMM socket levers.
B
Note location of alignment notch.
C
Insert DIMM making sure the connector edge
of the DIMM aligns correctly with the slot.
®
.
D
Push down firmly on the DIMM until it
snaps into place and both levers close.
E
IMPORTANT! Visually check that each
latch is fully closed and correctly
DIMM A2
engaged with each DIMM edge slot.
DIMM A1
DIMM B2
E
DIMM B1
DIMM C2
CPU 1 Socket
DIMM C1
DIMM D2
DIMM D1
DIMM E2
D
DIMM E1
DIMM F2
A
DIMM F1
CPU 2 Socket
11
(Optional) Install Intel®
C
SAS Entry RAID Module
AXX4SASMOD
A
Insert the three snap-standoffs into the
D
matching holes in the workstation board.
B
Attach the AXX4SASMOD module to the
workstation board SAS module connector.
Press firmly to engage the snap standoffs.
Right-angle
B
C
SAS/SATA
(Optional) Connect SES or SGPIO cable to the
Cable Detail
matching connector on the AXX4SASMOD as
shown. Connect the other end of the SES or
SGPIO cable to the hot-swap hard disk
backplane if installed. DO NOT connect both
A
cables to the AXX4SASMOD SAS module.
D
(Optional) Install optional RAID 5 Activation
Key (AXXRAKSW5) to the AXX4SASMOD
NOTE: Use right-angle
SAS module RAID 5 key connector as shown.
SAS/SATA cables only
16
Install Add-in
Cards
See the documentation that
came with your server chassis
for add-in card installation.
Attach system
fan with 3 or
For the Intel
Server Chassis
®
4-pin
SC5600 and the SC5650,
connectors
see the Quick Start User's Guide
here.
accompanying the chassis.
Attach active
processor
heat sink here.
Not for Intel
®
Server Chassis
SC5600Base.
Intel
®
Server Chassis SC5600Base
Intel
®
Server Chassis SC5650WS
Serial B
Intel
®
Server Chassis SC5600Base
Intel
®
Server Chassis SC5650WS
Front Panel
USB Front Panel
SATA
Intrusion
HSBP A
Intel
®
Server Chassis SC5600Base
Intel
®
Server Chassis SC5650WS
HSBP B
Main Power
Either SAS SES or SGPIO
Either SAS SES or SGPIO
Either SAS SES or SGPIO
Either SAS SES or SGPIO
Chass. Fan 1-4
8
Install Heat Sink(s)
Active processor heat sink(s) is required in the Intel
Chassic SC5600Base and SC5650WS.
For a non-Intel chassis, see the documentation accompanying your chassis.
CAUTION: The heat sink has thermal interface material
(TIM) on the underside of it. Use caution so that you do
not damage the thermal interface material. Use gloves to avoid
sharp edges. A second heat sink is required for a second processor.
A
If a protective film covers the thermal interface material (TIM) on the
underside of the heatsink, remove the protective film.
B
Align active heat sinks in the Intel
®
Server Chassis SC5600Base
and SC5650WS to let air flow go through to the center of the
C
board.
C
Using a #2 Phillips* screwdriver, finger-tighten each
fastener diagonally, according to the white-circled numbers.
D
Securely re-tighten each fastener again in the same order as
performed in Step C.
B
E
Attach active heatsink fan power cable to server board as shown.
12
13
Attach Intrusion Switch
Cable Accompanying Your
Chassis (for Non-Intel Chassis)
Note: For a non-Intel chassis, see your chassis
Note: For a non-Intel chassis, see your chassis
documentation for intrusion switch requirements.
documentation for intrusion switch requirements.
Workstation
Board
Serial B
Intrusion
Intrusion
Switch
Connector
17
Finishing Up
Network
Before installing your operating system, you
must finish your chassis installation, make
NIC1
NIC2
I/O connections and plug in AC power.
10/100/
10/100/
1000 Mb
1000 Mb
1394
Serial A
Audio
USB
USB
CAUTION: See your chassis
documentation for AC power and
grounding requirements.
Intel® Workstation Board S5520SC
CPU Fan 1
Chass. Fan 5
Component Layout
CPU 1 Power
CPU 1 Socket
ME Force
Update
RAID 5 Key
Password
Clear
Intrusion
BMC Force Update
CPU 2 Socket
CPU 2 Power
CPU 2 Fan
Aux. Power
A
C D
C
CAUTION:
Note: Heatsink
3
Do not
T
styles may vary
Server
®
over-tighten
I
fasteners.
V
E
B
2
1
A
TIM
4
B
E
14
Attach Front Panel,
(Optional) Install Intel® Remote Management
Serial, and USB
Module 3
Connections
A
Attach the RMM3 module to
the add-in card bracket as
shown. Note: The RMM3
installs the same way as
an add-in card. See your
B
chassis documentation
Workstation
for add-in card
Board
Ribbon
installation
Cable
procedures.
B
Install the
Front
RMM3 in an
Panel
add-in card
slot near the
workstation board
USB
RMM3 header.
C
Attach the RMM3 ribbon cable. Make
sure each connector end is securely seated.
18
Software
BIOS, Firmware, Drivers, and
Operating System Installation
A. Confirm BIOS Version:
Confirm BIOS, BMC, and FRUSDR Versions. Look on
the Server/System Management screen in the BIOS Setup Utility to determine the installed
BIOS, BMC firmware, and FRUSDR version. Compare these to the versions at:
http://support.intel.com/support/motherboards/server/S5520SC/
If new versions are available, see the Intel
®
Workstation Board S5520SC Week Technical
Update to update the BIOS, BMC, and FRUSDR on your server.
B. Configure your RAID Controller:
Use the instructions provided with the
RAID controller.
C. Install your Operating System:
Use the instructions provided with the
RAID controller and with the operating system.
D. Install Operating System Drivers:
With the operating system running,
insert the Intel
®
Server Deployment Toolkit 3.0 CD, which comes with the production version
of the Intel
Workstation Board S5520SC. If using a Microsoft Windows* operating
®
system, the Intel
®
Deployment Assistant (in the Deployment Toolkit 3.0 CD) will autorun and
allow you to select the appropriate drivers to install. On other operating systems, browse the
CD folders to locate and install the driver files.
Note: Refer to the
Technical Product
Specification for
Diagnostic LED
ID LED
decoder list.
Status LED
Front
Diagnostic LEDs
Panel
Audio
LSB
MSB
NIC 2
NIC 1
Serial A
CPU 1
USB 0
USB 2
Audio
Power
1394
USB 1
USB 3
Slot 1
PCI Express* Gen2 x16
S/PDIF
(32bit/33MHz PCI, 5V)
(slot 4, 6)
CPU 1
Header
Battery
Fan
Sys Fan 5
Serial B
Header
Front
Panel
Header
CMOS Clear
Internal
Video
USB
1394
USB SSD
USB
HDD Activity LED
SATA 5
CPU 1 Socket
ICH10
SATA 4
BIOS Recover
SATA RAID 5 Key
SATA 3
HSBP A
SATA 2
SATA
HSBP B
SGPIO
SATA 1
LCP/
IPMB
IOH
SATA 0
USB
Main Power
Sys Fan 3
CPU 2 Socket
Sys Fan 1
SAS Module
CPU 2
Slot
Power
Sys Fan 2
Sys Fan 4
CPU 2 Fan
Aux Pwr Signal
9
Install Optical
Drive and
Hard Drive(s)
See the documentation that
CPU 1 Socket
came with your server chassis
A
for drive installation.
I
R
F
L
O
W
A
I
R
F
L
O
W
CPU 2 Socket
RMM3 Module
Header
IMPORTANT NOTE:
A
Return to your Intel
®
Server Chassis Quick
Start User's Guide, or
your non-Intel chassis
documentation to finish
installation and
configuration of your
C
Intel
Workstation
®
Board S5520SC.
Return to this document
to finish up, including
software, BIOS, drivers
RMM3
Workstation
and operating system
Board Header
installation.
Common Problems and Solutions
For a list of hardware components that have been tested with
this system, see:
http://support.intel.com/support/motherboards/
server/s5520SC/
The system does not boot or show video at power-on:
Check that all processor power connectors are plugged-in.
I
Without these connections, the server cannot boot.
Beep code 3 means you have bad memory; replace the faulty
I
DDR3 DIMM(s).
Remember, all DIMMs must be:
I
• DDR3 800/1066/1333-compliant, 240-pin DIMMs.
• No mixing of DDR3 RDIMMs and UDIMMs.
• Installed beginning with first slot of each channel.
• Install Quad-Rank DIMM from first slot of each channel.
The system sometimes works, but is exhibiting erratic behavior.
This is probably the result of using an underrated power supply.
I
Accessories and Order Codes
®
Intel
Remote Management Module 3
AXXRMM3
®
AXX4SASMOD
Intel
SAS Entry RAID Module
Intel
®
RAID Activation Key (SATA / SAS Software RAID 5)
AXXRAKSW5
Intel
®
Server Chassis SC5600Base
SC5600Base
®
Intel
Server Chassis SC5650WS
SC5650WS
®
Video Cable Kit for Intel
Workstation Board S5520SC on-board Video
FXXSCVDCBL
®
A complete list of accessories and spares can be found in the Intel
Workstation Board S5520SC
Configuration Guide.
Available Documents
Document Type
Content
Technical Product Specification
In-depth technical information
Spares and Configuration Guide
Supported accessories and spares list
Server Configurator Tool
Tested peripherals and operating systems list
Tested memory list
Supported processors list
Software and Drivers
Up-to-date firmware, driver and utility information
Additional Reference documents available at:
http://support.intel.com/support/motherboards/
server/S5520SC/

Advertisement

loading