Walchem W600 Series Instruction Manual page 40

Metal finishing controller
Hide thumbs Also See for W600 Series:
Table of Contents

Advertisement

Inputs
Nickel (S11)
ph (S12)
Temp (S13)
Generic AI (S21)
> Calibration
SENSOR (S1)
Water/Sample Calibration
One Point Process Calibration
One Point Buffer Calibration
Two Point Buffer Calibration
Three Point Buffer Calibration
One Point Analog Calibration
Two Point Analog Calibration
Open Air Calibration (Cond)
Zero Calibration (Disinfection)
Additional Settings for Contacting Conductivity:
Contacting Cond S11 (22)
Alarm Suppression
Alarms
Smoothing Factor
Deadband
Default Temp
Reset Calibration Values
Temp Compensation
Cal Required Alarm
Temp Comp Factor
Cell Constant
Additional Settings for Electrodeless Conductivity:
Electrodeless Cond S11 (S21)
Alarm Suppression
Alarms
Smoothing Factor
Deadband
Default Temp
Reset Calibration Values
Installation Factor
Cal Required Alarm
Range
Temp Compensation
Temp Comp Factor
Temperature S12 (S22)
Additional Settings for Temperature Sensor:
Alarm Suppression
SENSOR (S1)
Alarms
Smoothing Factor
Deadband
Name
Reset Calibration Values
Element
Cal Required Alarm
pH S11 (S21)
Additional Settings for pH Sensor:
SENSOR (S1)
Alarm Suppression
Alarms
Smoothing Factor
Deadband
Buffers (pH only)
Reset Calibration Values
Default Temp
Cal Required Alarm
Cable Length
ORP S11 (S21)
Additional Settings for ORP Sensor:
SENSOR (S1)
Alarm Suppression
Alarms
Smoothing Factor
Deadband
Cable Length
Reset Calibration Values
Gauge
Cal Required Alarm
Additional Settings for Disinfection Sensor:
Disinfection S11 (S21)
Alarm Suppression
SENSOR (S1)
Alarms
Smoothing Factor
Deadband
Cable Length
Reset Calibration Values
Gauge
Cal Required Alarm
Name
Sensor
Type
Additional Settings for Generic Sensor:
Generic S11 (S21)
Alarm Suppression
Alarms
SENSOR (S1)
Smoothing Factor
Deadband
Sensor Slope
Reset Calibration Values
Sensor Offset
Cal Required Alarm
Low / High Range
7.00 g/l
4.50
77.1°F
30.5%
INPUTS
Transmitter S11 (S12,13,21,22,23)
AI Monitor S11 (S12,13,21,22,23)
Cable Length
Alarms
Gauge
Deadband
Units
Reset Calibration Values
Name
Cal Required Alarm
Type
Fluorometer S11 (12,13, 21,22, 23)
Alarms
Cell Constant
Deadband
Cable Length
Reset Calibration Values
Gauge
Cal Required Alarm
Units
Name
Type
Calculation (V1-V2)
Alarms
Deadband
Input
Input 2
Raw Value (V1-V2)
Alarms
Deadband
Alarm Suppression
Input
Gauge
Electrode
Name
Type
DI State (D1-D6)
SENSOR (S1)
Open Message
Closed Message
Interlock
Alarm
Name
Type
Contactor Type
Flowmeter (D1-D6)
SENSOR (S1)
Totalizer Alarm
Reset Flow Total
Set Flow Total
Scheduled Reset
Paddlewheel Type
Flowmeter (D1-D6)
Totalizer Alarm
Reset Flow Total
Set Flow Total
Scheduled Reset
Cable Length
Gauge
Units
Name
Type
Feed Monitor (D1-D6)
SENSOR (S1)
Totalizer Alarm
Reset Flow Total
Set Flow Total
Scheduled Reset
36
Main Menu
09:19:01
14-Mar-2017
Config
Inputs
Outputs
HOA
Alarms
Graph
Inputs>Sensor (S11)
Details Screen
Content varies with
sensor type
Additional Settings for Transmitter and AI Monitor:
Alarm Suppression
Smoothing Factor
4 mA Value
20 mA Value
Additional Settings for Fluorometer:
Alarm Suppression
Smoothing Factor
Max Sensor Range
Dye / Product Ratio
Additional Settings for Virtual Input
Calculation Mode
Alarm Suppression
Low Range
High Range
Smoothing Factor
Name
Type
Additional Settings for Raw Value:
Smoothing factor
Name
Type
Additional Settings for DI State:
Total Time
Reset Time Total
Name
Type
Additional Settings for Contactor, Flowmeter:
Volume/Contact
Flow Units
Name
Type
Additional Settings for Paddlewheel, Flowmeter:
K Factor
Flow Units
Rate Units
Smoothing Factor
Name
Type
Additional Settings for Feed Monitor:
Total Alarm Mode
Flow Alarm Mode
Flow Alarm Delay
Flow Alarm Clear
Deadband
Reprime Time
Volume/Contact
Units
Name
Type
Name
Type
Flow Units
Rate Units
Smoothing Factor
Output
Name
Type