Data contains conditions and values that are written
after the header. A space separates the data from the
header. Data is grouped as follows:
Data
Description
<Decimal>
A value expressed in decimal notation
Example: Probe attenuation for CH1
-> CHANnel1:PROBe 100
<Voltage><Time><Frequency><Current>
A physical value
Example: Time-axis range
-> TIMebase:TDIV 1US
<Register>
A register value expressed as binary,
octal, decimal or hexadecimal
Example: Extended event register value
-> STATUS:EESE #HFE
<Character data>
Predefined character string (mnemonic).
Select from the available strings in braces.
Example: Select the input coupling of CH1
-> CHANnel1:COUPling {AC|DC|
GND|TC}
<Boolean>
Indicates on and off. Specify ON, OFF,
or a value
Example: Turn on the CH1 display
-> CHANnel1:DISPlay ON
<String data>
User-defined string
Example: Comment attached to screen
-> HCOPy:COMMent "ABCDEF"
<Filename>
Indicates a file name.
Example: Save file name
-> FILE:SAVE:NAME "CASE1"
<Block data>
Data that contains 8-bit values
Example: Response to acquired
-> #800000010ABCDEFGHIJ
<Decimal>
<Decimal> indicates a value expressed as a decimal
number, as shown in the table below. Decimal values
are written in the NR form as specified in ANSI X3.42-
1975.
Symbol Description
<NR1>
Integer
<NR2>
Fixed point number
Floating-point number 125.0E+0 -9E-1 +.1E4
<NR3>
<NRf>
Any form from <NR1> to <NR3>
• The instrument can receive decimal values that are
sent from the controller in any form, from <NR1> to
<NR3>. This is expressed as <NRf>.
• The instrument returns a response to the controller
in one of the forms from <NR1> to <NR3>
depending on the query. The same form is used
regardless of the size of the value.
• For the <NR3> form, the plus sign after the "E" can
be omitted. You cannot omit the minus sign.
3-6
data output
waveform data
Examples
125
-1
+1000
125.0
-.90
+001.
• If a value outside the setting range is entered, the
value is adjusted to the closest value within the range.
• If a value has more significant digits than are
available, the value will be rounded.
<Voltage>, <Time>, <Frequency>, <Current>
<Voltage>, <Time>, <Frequency>, and <Current>
indicate decimal values that have physical significance.
A <Multiplier> or <Unit> can be attached to the <NRf>
form that was described earlier. The following types of
expressions are possible.
Form
<NRf><Multiplier><Unit>
<NRf><Unit>
<NRf><Multiplier>
<NRf>
• <Multiplier>
<Multipliers> that you can use are indicated in the
following table.
Symbol
Word
EX
Exa
PE
Peta
T
Tera
G
Giga
MA
Mega
K
Kilo
M
Milli
U
Micro
N
Nano
P
Pico
F
Femto
A
Atto
• <Unit>
<Units> that you can use are indicated in the
following table.
Symbol
Word
V
Volt
S
Second
HZ
Hertz
MHZ
Megahertz
A
Ampere
• <Multiplier> and <Unit> are not case sensitive.
• "U" is used to indicate micro ("μ").
• "MA" is used for Mega to distinguish it from Milli.
Megahertz, which is expressed as "MHZ," is an
exception. Therefore, "M (Milli)" cannot be used for
frequencies.
• If both <Multiplier> and <Unit> are omitted, the
default unit is used.
• Response messages are always expressed in the
<NR3> form. Response messages are returned using
the default unit without the <Multiplier> or <Unit>.
Example
5MV
5E-3V
5M
5E-3
Multiplier
10
18
15
10
10
12
9
10
6
10
10
3
–3
10
10
–6
–9
10
–12
10
–15
10
–18
10
Description
Voltage
Time
Frequency
Frequency
Current
IM DL350-17EN