M ai n ten a nc e /T r o u b l e s h o o t in g
9.5

Messages on the display and the "Fault" LED

Many fault signals indicate a fault in the grid. They are not operational faults of the inverter. The minimum triggering
levels are determined by standards (e.g. VDE 0126-1-1). The inverter must switch off if the permitted values are
undershot or exceeded.
9.5.1
Display of status and fault messages
Display
FS (fault status)
OS (operating status)
On the display you can fi nd details regarding the fault or operating status or the data that was recorded through the
RS485 interface.
9.5.2
Status and fault signals
The following table lists the possible status and fault signals that the inverter shows on the LCD and the LEDs.
Status
Display
OS 1
Waiting for feed-in
OS 2
Generator voltage
too low
OS 7
Self-test
OS 75
Self-test
OS 8
Self-test
FS
10
Temperature in
unit too high
Table 6:
Operating states and fault messages on the display
OS = operating status, FS = fault status;
B = Action of the operator
E = The indicated work must only be carried out by an authorised electrician.
K = The indicated work must only be carried out by a service employee of KACO new energy GmbH.
Page 46
Fault LED (red)
ON
OFF
Explanation
Self test: Grid parameters and genera-
tor voltage are being checked.
Generator voltage and power are too
low; situation before transition into
night shutdown
Checks the shutdown of the power
electronics as well as the line relay
before feed-in mode. The self-test
consists of three successive individual
tests with the status 7, 75 and 8.
In case of overheating, the inverter
switches off . Possible causes:
Ambient temperature too high
Fans covered
Inverter defect
Fault signal relay has switched.
Feed-in was ended due to a fault.
The fault signal relay deenergizes again.
The inverter feeds back into the grid again
after a country-specifi c time period.
Action
-
-
-
 Cool off the vicinity
 Uncover the fans.
 Notify your autho-
Operating Instructions Powador 10.0 TL3, 12.0 TL3, 14.0 TL3_EN
By
-
-
-
B
of the inverter.
B
E
rised electrician.