EXCITE + - VARIO: Technical service guide- Ver. 2.1
Follow the procedure step by step to correctly diagnose the problem. Take particular care with the
checks highlighted by circled numbers, which are described in detail below:
(1)
Check the correct display SW version, according to the "EXCITE SW SMART TABLE" you
can find in TG Direct section.
(2)
Check if the receiver has been correctly mounted on the machine, as detail at paragraph:
Errore. L'origine riferimento non è stata trovata."Errore. L'origine riferimento non è
stata trovata.".
(3)
Place the tester probes across pins 1 and 2 on CN1 connector of receiver. The measured value
should be +5Vdc.
(4)
As at step (1) but on pin 1 and 8 on CN3 connector of CU291 cable (ARM Board).
If you replace ARM Board, check that its SW version is updated, otherwise install the
last version.
Page 6.39