Technogym EXCITE+ VARIO Technical Service Manual page 104

Table of Contents

Advertisement

Replace the connectoring
cables between the High
Kit and Low Kit.
Page 6.32
THERE IS NO
HR SIGNAL
(Hand Sendor)
Check if using a chest belt
that you are sure it's ok, it works
properly.
The problem persists?
Check if the +5Vdc are at the
input of Receiver Board.
Are them present?
YES
Check if the +5Vdc are at the
output of the ARM/CPU Board.
Are them present?
ARM/CPU Board
defective.
Replace.
EXCITE + - VARIO: Technical service guide- Ver. 2.1
YES
A
NO
1
YES
NO
2
NO
Continued on following page ...
OK
NO
3
Check if the SW and the
gruonding of Receiver Board.
The problem persist?
YES
Receiver Board
defective.
Replace.