Operation parameters

Please note - changing operation parameters without the expressed
consent from Gram Commercial A/S can have unintended implications
on performance and potentially void warranty.
Press
for 5 seconds to enter operation parameters.
Operation parameters
Sensor read-out
18 |
BIOBASIC MANUAL
Unit
Offset of A-sensor. Reference sensor
CA
[° K]
for refrigeration and alarm system
Number of defrosts per 24 hours (4
d1
is factory setting)
Termination temperature in the
d2
[° C]
evaporator during a defrost
*Only for glass door models* -
Li
On/off
Turn light on or off
tEr
Relay test / Component test
tC
[° C]
Test compressor relay
tF
[Min.] Test evaporator fan
Test defrost element relay (RF
td
[Min.]
models)
Test alarm relay (will trip voltage
tA
[Min.]
free)
tdP
On/off Test display
P-A
[° C]
Test output of A-sensor
P-B
[° C]
Test output of B-sensor