Removal Procedure Of Indoor Unit; Remove Filter; Remove Horizontal Louver - Gree GWH12ACC-K6DNA1D Service Manual

Hide thumbs Also See for GWH12ACC-K6DNA1D:
Table of Contents

Advertisement

11. Removal Procedure

11.1 Removal Procedure of Indoor Unit

Step

1. Remove filter

a
Open the panel.
b
Loosen the clasp shown in the fig and
then pull the left filter and right filer
outwards to remove them.

2. Remove horizontal louver

Push out the axile bush on horizontal
louver. Bend the horizontal louver with
hand and then separate the horizontal
louver from the crankshaft of step motor
to remove it.
94
Caution: discharge the refrigerant
completely before removal.
Procedure
Panel
Clasps
Left filter and right filer
09/12K
Horizontal louver
18/24K
Horizontal louver
Axile bush
Location of step motor
Axile bush
Location of step motor
Installation and Maintenance
Service Manual

Hide quick links:

Advertisement

Table of Contents
loading