Gree GWH12ACC-K6DNA1D Service Manual page 61

Hide thumbs Also See for GWH12ACC-K6DNA1D:
Table of Contents

Advertisement

Display Method of Indoor Unit
Dual-8
Malfunction
No.
Code
Name
Display
Decrease
frequency
19
due to
F9
high air
discharge
Limit/
decrease
20
frequency
FH
due to
antifreezing
Voltage for
21
DC bus-bar
PH
is too high
Voltage of
22
DC bus-bar
PL
is too low
Compressor
Min
23
P0
frequence in
test state
Compressor
rated
24
P1
frequence in
test state
Compressor
maximum
25
P2
frequence in
test state
58
Indicator Display (during
blinking, ON 0.5s and OFF
0.5s)
operation
Cool
Heating
Indicator
Indicator
Indicator
All loads operate normally, while
operation frequency for
compressor is decreased
All loads operate normally, while
operation frequency for compressor is
decreased
During cooling and drying
operation, compressor will stop
while indoor fan will operate;
During heating operation, the
complete unit will stop operation.
During cooling and drying
operation, compressor will stop
while indoor fan will operate;
During heating operation, the
complete unit will stop
A/C status
Overload or temperature is too high;
Refrigerant is insufficient;
Malfunction of electric expansion valve (EKV)
Poor air-return in indoor unit or fan speed is too
low
1. Measure the voltage of position L and N on
wiring board (XT), if the voltage is higher than
265VAC, turn on the unit after the supply voltage
is increased to the normal range.
2.If the AC input is normal, measure the voltage
of electrolytic capacitor C on control panel (AP1),
if its normal, theres malfunction for the circuit,
please replace the control panel (AP1)
1. Measure the voltage of position L and N on
wiring board (XT), if the voltage is higher than
150VAC,
turn on the unit after the supply voltage is
increased to the normal range.
2.If the AC input is normal, measure the voltage
of electrolytic capacitor C on control panel (AP1),
if its normal, theres malfunction for the circuit,
please replace the control panel (AP1)
Showing during min. cooling or min. heating test
Showing during nominal cooling or nominal
heating test
Showing during max. cooling or max. heating test
Service Manual