Diagnostics
The Diagnostics page provides detailed information
regarding the current status of the recorder and the
accessories connected to it.
This information can be useful when troubleshooting
certain issues. All of the fields in the Diagnostics page are
for display only and cannot be changed.
NOTE: Page will refresh at every 1 sec.

Temperature

Shows the current temperature of the NVR in Celsius.

Accelerometer

Shows the current 3-dimension acceleration.

Trigger 1 - Trigger 4

It will show Sensor 1 to Sensor 4 name and its current status.
If voltage is applied to the sensor, it will show voltage and
sensor as Active only if the applied voltage is greater than
the sensor's configured threshold. Otherwise, it will display 0
voltage and Inactive status.

Ignition

Shows the current status of the ignition as ON or OFF.

Current Voltage

Shows the current vehicle power in millivolts (mV).
Relay 1 - Relay 4
Shows the current status of Digital Out i.e. relay either as ON