Product Overview - Hach TU5300 sc Basic User Manual

Hide thumbs Also See for TU5300 sc:
Table of Contents

Advertisement

residential area is likely to cause harmful interference, in which case the user will be required to
correct the interference at their expense. The following techniques can be used to reduce
interference problems:
1. Disconnect the equipment from its power source to verify that it is or is not the source of the
interference.
2. If the equipment is connected to the same outlet as the device experiencing interference, connect
the equipment to a different outlet.
3. Move the equipment away from the device receiving the interference.
4. Reposition the receiving antenna for the device receiving the interference.
5. Try combinations of the above.

Product overview

Chemical or biological hazards. If this instrument is used to monitor a treatment process and/or
chemical feed system for which there are regulatory limits and monitoring requirements related to
public health, public safety, food or beverage manufacture or processing, it is the responsibility of the
user of this instrument to know and abide by any applicable regulation and to have sufficient and
appropriate mechanisms in place for compliance with applicable regulations in the event of malfunction
of the instrument.
The TU5300 sc and the TU5400 sc turbidimeters are used with an SC controller to measure low-
range turbidity mostly in finished drinking water applications. Refer to
The TU5300 sc and the TU5400 sc turbidimeters measure scattered light at an angle of 90° in a 360°
radius around the axis of the incident light beam.
An optional RFID module and an automatic system check option are available
shown in
Figure
1. The RFID module lets process and laboratory turbidity measurements be easily
compared. A description of the automatic system check option is given in the expanded user manual
on the manufacturer's website.
PROGNOSYS predictive diagnostic software is available for the TU5300 sc and TU5400 sc
turbidimeters. To use PROGNOSYS, connect the turbidimeter to an SC controller with
PROGNOSYS.
Videos on how to install, operate and do maintenance and troubleshooting on the TU5300 sc and the
TU5400 sc turbidimeters are available on the TU5 Series Turbidimeters playlist at
http://www.youtube.com/user/hachcompany.
For the accessories, refer to the expanded user manual on the manufacturer's website.
4
The RFID module and automatic system check option is only available at the time of purchase.
8 English
D A N G E R
Figure
1.
4
. The RFID module is

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tu5400 sc

Table of Contents