20
13. Rate of smooth level control
Parameter allows to choose how long the hand has to be held near the
center of the pad after "AirWheel" gesture for the associated devices to
reach their maximum/minimum level.
Available settings: 0-10 - duration in seconds
Default setting:
ASSOCIATIONS - CONTROL FRAMES CONFIGURATION
i
NOTE
20. SWITCH ON control frame value for FLICK UP gesture
Commands sent to
This parameter allows to set value sent in SWITCh On command
association group for
frame to the association group.
turn On/OFF can be
adjusted in parame-
Available settings: 0-99 or 255
ters 20-27.
Default setting:
21. SWITCH OFF control frame value for FLICK UP gesture
This parameter allows to set value sent in SWITCh OFF command
i
NOTE
frame to the association group.
Setting
parameters
Available settings: 0-99 or 255
20-27 to appropriate
Default setting:
value will result in:
0 - turning off associ-
22. SWITCH ON control frame value for FLICK DOWN gesture
ated devices
This parameter allows to set value sent in SWITCh On command
1-99 - forcing level of
frame to the association group.
associated devices
255 - setting associat-
Available settings: 0-99 or 255
ed devices to the last
Default setting:
remembered state or
turning them on
23. SWITCH OFF control frame value for FLICK DOWN gesture
This parameter allows to set value sent in SWITCh OFF command
frame to the association group.
Available settings: 0-99 or 255
Default setting:
24. SWITCH ON control frame value for FLICK LEFT gesture
This parameter allows to set value sent in SWITCh On command
frame to the association group.
Available settings: 0-99 or 255
Default setting:
ASSOCIATIOnS
255 - default settings of controlled devices
255
Parameter size:
2 [bytes]
255
Parameter size:
2 [bytes]
0
Parameter size:
2 [bytes]
255
Parameter size:
2 [bytes]
0
Parameter size:
2 [bytes]
255
2 [bytes]
Parameter size:
25. SWITCH OFF control frame value for FLICK LEFT gesture
This parameter allows to set value sent in SWITCh OFF command
frame to the association group.
Available settings: 0-99 or 255
0
Default setting:
Parameter size:
26. SWITCH ON control frame value for FLICK RIGHT gesture
This parameter allows to set value sent in SWITCh On command
frame to the association group.
Available settings: 0-99 or 255
Default setting:
255
Parameter size:
27. SWITCH OFF control frame value for FLICK RIGHT gesture
This parameter allows to set value sent in SWITCh OFF command
frame to the association group.
Available settings: 0-99 or 255
0
Default setting:
Parameter size:
SEQUENCES OF GESTURES
30. Sequence learning mode
Parameter activated by the main Z-Wave controller. Change its value to
launch sequence learning procedure for the desired slot.
Available settings: 0 - learning mode disabled
1-6 - launch sequence learning for selected slot
0
Default setting:
Parameter size:
31. 1st gestures sequence (SLOT 1)
value containing sequence of gestures. See "Sequences of gestures" on
page 12 for more information.
Available settings: 0-1076
Default setting:
0
Parameter size:
32. 2nd gestures sequence (SLOT 2)
value containing sequence of gestures. See "Sequences of gestures" on
page 12 for more information.
Available settings: 0-1076
0
Default setting:
Parameter size:
21
2 [bytes]
2 [bytes]
2 [bytes]
i
NOTE
Sequences does not
allow to use same
gestures next to each
other.
1 [byte]
i
NOTE
Parameters 31-36 can
also be used to manu-
ally set a sequence ac-
cording to details de-
2 [bytes]
scribed in "Sequences
of gestures" on page
12.
2 [bytes]
ASSOCIATIOnS