Configure PON1 port vlan mode is hybird:
OLT(config)# interface epon 0/0
OLT(config-interface-epon-0/0)# vlan mode 1 hybrid
OLT(config-interface-epon-0/0)# vlan hybrid 1 tagged 100,200,300
OLT(config-interface-epon-0/0)# exit

6.3.4 Configure OLT Multicast Service

Configure IGMP and multicast-vlan 200
OLT(config)# igmp mode snooping
OLT(config)# multicast-vlan 200
OLT(config-multicast-vlan-200)# igmp program add program-index 1 ip 224.3.3.3
OLT(config-multicast-vlan-200)# igmp router-port ge 0/0/6
OLT(config-multicast-vlan-200)# btv
OLT(config-btv)# igmp user add user-index 1 pon 0/0/2 ont 2 vlan 1000 no-auth
OLT(config-btv)# multicast-vlan 200
OLT(config-multicast-vlan-200)# igmp member user-index 1
OLT(config-multicast-vlan-200)# exit
NOTE:
igmp program add program-index command is used to create multicast program table. Only the
program table in the multicast vlan, the user can watch the program. Create multicast program
table can use igmp program add program-index <1-2000> batch command to batch add program
or use igmp program add program-index <1-2000> ip command to add program single.

6.4 Create ONU Profile

EPON ONU profile include DBA-profile,ont-lineprofile,ont-srvprofile.
DBA profile:DBA profile describes the EPON flow parameters,the LLID bind DBA profile to
distribute bandwidth dynamically,and increases utilization of uplink bandwidth.
ont-lineprofile:ont-lineprofile describes the bind relationship of LLID and DBA profile,FEC
mode,QOS mode and so on.
ont-srvprofile:ont-srvprofile provides a service configuration channel for ONU manage by
oam.such as ONU port vlan configure,ONU igmp configure.

6.4.1 Create ONU DBA Profile

Use show dba-profile all command to query the existing DBA profile in the system,if the existing
DBA profile can't meet the demand,we need use dba-profile to add DBA profile.Create different
DBA profile for different service type.
Create dba profile number is 1,type is Type3,assure bandwidth is 8Mbit/s,max bandwidth is
20Mbit/s:
OLT(config)# dba-profile profile-id 1
OLT(dba-profile-1)# type3 assure 8192 max 20480
Company Address: Flat 6, Bldg 4,South 2 of Honghualing Industrial Zone,Liuxian Road, Xili Town, Shenzhen, Guangdong, China(518055)
Factory Address: Fl1, Bldg B, Wentao Industrial zone, Yingrenshiyongxin Village, Shiyan Street, Baoan district, Shenzhen, Guangdong, China (518055)