Configure Olt Multicast Service; Check Onu Register Status; Configure Bridge Onu(Sfu) Service; Configure Bridge Onu(Sfu) Internet Service - C-Data FD1204S Configuration Manual

Epon olt products
Table of Contents

Advertisement

5.4.4 Configure OLT Multicast Service

Configure IGMP and multicast-vlan 200
OLT(config)# igmp mode snooping
OLT(config)# multicast-vlan 200
OLT(config-multicast-vlan-200)# igmp program add program-index 1 ip 224.3.3.3
OLT(config-multicast-vlan-200)# igmp router-port ge 0/0/6
OLT(config-multicast-vlan-200)# btv
OLT(config-btv)# igmp user add user-index 1 pon 0/0/2 ont 2 vlan 1000 no-auth
OLT(config-btv)# multicast-vlan 200
OLT(config-multicast-vlan-200)# igmp member user-index 1
OLT(config-multicast-vlan-200)# exit
NOTE:
igmp program add program-index command is used to create multicast program table. Only the
program table in the multicast vlan, the user can watch the program. Create multicast program
table can use igmp program add program-index <1-2000> batch command to batch add program
or use igmp program add program-index <1-2000> ip command to add program single.

5.5 Check ONU Register Status.

In OLT discrete mode,ONU is automatically registered,after ONU is automatically registered,use
command show ont info to query ONU online status.make sure ONU "Control flag" is " Active" , " Run
State"is"Online","Config state"is"Success"and"Match state"is"Match"
OLT(config-interface-epon-0/0)# show ont info 1 all
-----------------------------------------------------------------------------
F/S P ONT MAC
----------------------------------------------------------------------------
0/0 1 1
0/0 1 2
----------------------------------------------------------------------------
Total: 2, online 2

5.6 Configure Bridge ONU(SFU) Service

In OLT discrete mode,we need enter OLT to config ONU one by one,config way as follows:

5.6.1 Configure Bridge Onu(SFU) Internet Service

Premise condition of ONU to open internet service:
OLT connect to uplink device and open internet service
Company Address: Flat 6, Bldg 4,South 2 of Honghualing Industrial Zone,Liuxian Road, Xili Town, Shenzhen, Guangdong, China(518055)
Factory Address: Fl1, Bldg B, Wentao Industrial zone, Yingrenshiyongxin Village, Shiyan Street, Baoan district, Shenzhen, Guangdong, China (518055)
Tel: +86-755-26014509/4710/4711 Fax:+86-755-26014506
Website: www.cdatatec.com
Control
ID
flag
E0:67:B3:09:F0:21
active
E0:67:B3:12:05:3E
active
Run
Config
Match
state
state
state
online
success match
online
success match
Desc
12

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for C-Data FD1204S

This manual is also suitable for:

Fd1208sFd8000-l116Fd1216s

Table of Contents