Hardware Installation Manual
5
Cabling the Device
This section describes how to cable the device:
Connecting to earth or ground (see Section
Connecting to the WAN (see Section
Connecting to the LAN (see Section
Connecting to Analog Devices (see Section
Connecting the Analog Lifeline (see Section
Connecting to BRI lines (see Section
Connecting the PSTN Fallback for BRI lines (see Section
Connecting to E1/T1 trunks (see Section
Connecting the E1/T1 trunks for PSTN Fallback (see Section
Connecting to a PC for serial communication (see Section
Connecting to power (see Section
5.1
Grounding the Device
The procedure below describes how to ground the device.
The equipment is classified as Class I EN 60950 and UL 60950 and must be
earthed at all times (using an equipment-earthing conductor).
•
Finland: "Laite on liltettava suojamaadoituskoskettimilla varustettuun
pistorasiaan."
•
Norway: "Apparatet rna tilkoples jordet stikkontakt."
•
Sweden: "Apparaten skall anslutas till jordat uttag."
To ground the device:
1.
Connect an electrically earthed strap of 16 AWG wire (minimum) to the chassis'
earthing screw (located on the rear panel), using the supplied washer.
2.
Connect the other end of the strap to a protective earthing. This should be in
accordance with the regulations enforced in the country in which the device is
installed.
MSBR Series
5.2
5.3
5.5.1
5.8
on page 49)
Protective Earthing
Figure 5-1: Grounding the Device
35
5.1
on page 35)
on page 36)
on page 39)
5.4.2
on page 41)
5.4.3
on page 41)
on page 43)
5.5.2
5.6.1
on page 45)
5.6.2
5.7
on page 47)
5. Cabling the Device
on page 44)
on page 46)
Mediant 1000B MSBR