Daikin ERLQ004CA Installer's Reference Manual page 99

Daikin altherma - low temperature split
Hide thumbs Also See for ERLQ004CA:
Table of Contents

Advertisement

6/9
Field settings table
Breadcrumb
Field code
Setting name
A.8
[2-02]
When should the disinfection function start?
A.8
[2-03]
What is the disinfection target temperature?
A.8
[2-04]
How long must the tank temperature be maintained?
A.8
[2-05]
Room antifrost temperature
A.8
[2-06]
Room frost protection
A.8
[2-09]
Adjust the offset on the measured room temperature
A.8
[2-0A]
Adjust the offset on the measured room temperature
A.8
[2-0B]
What is the required offset on the measured outdoor temp.?
A.8
[3-00]
Is auto restart of the unit allowed?
A.8
[3-01]
--
A.8
[3-02]
--
A.8
[3-03]
--
A.8
[3-04]
--
A.8
[3-05]
--
A.8
[3-06]
What is the maximum desired room temperature in heating?
A.8
[3-07]
What is the mimimum desired room temperature in heating?
A.8
[3-08]
What is the maximum desired room temperature in cooling?
A.8
[3-09]
What is the minimum desired room temperature in cooling?
A.8
[4-00]
What is the BUH operation mode?
A.8
[4-01]
Which electric heater has priority?
A.8
[4-02]
Below which outdoor temperature is heating allowed?
A.8
[4-03]
Operation permission of the booster heater.
A.8
[4-04]
--
A.8
[4-05]
--
A.8
[4-06]
-- (Do not change this value)
A.8
[4-07]
Enable the second step of the backup heater?
A.8
[4-08]
Which power limitation mode is required on the system?
A.8
[4-09]
Which power limitation type is required?
A.8
[4-0A]
--
A.8
[4-0B]
Automatic cooling/heating changeover hysteresis.
A.8
[4-0D]
Automatic cooling/heating changeover offset.
A.8
[5-00]
Is backup heater operation allowed above equilibrium temperature during space
heating operation?
A.8
[5-01]
What is the equilibrium temperature for the building?
A.8
[5-02]
Space heating priority.
A.8
[5-03]
Space heating priority temperature.
A.8
[5-04]
Set point correction for domestic hot water temperature.
A.8
[5-05]
What is the requested limit for DI1?
A.8
[5-06]
What is the requested limit for DI2?
A.8
[5-07]
What is the requested limit for DI3?
A.8
[5-08]
What is the requested limit for DI4?
A.8
[5-09]
What is the requested limit for DI1?
A.8
[5-0A]
What is the requested limit for DI2?
A.8
[5-0B]
What is the requested limit for DI3?
A.8
[5-0C]
What is the requested limit for DI4?
A.8
[5-0D]
What type of backup heater installation is used?
A.8
[5-0E]
--
A.8
[6-00]
The temperature difference determining the heat pump ON temperature.
A.8
[6-01]
The temperature difference determining the heat pump OFF temperature.
4P383508-1B - 2017.04
Range, step
Default value
R/W
0~23 hour, step: 1 hour
23
R/W
[E-07]≠
55~80°C, step: 5°C
1 :
70°C
[E-07]=1 : 60°C
60°C
R/W
[E-07]≠1: 5~60 min, step: 5 min
10 min
[E-07]=1: 40~60 min, step: 5 min
40 min
R/W
4~16°C, step: 1°C
12°C
R/W
0: Disabled
1: Enabled
R/W
-5~5°C, step: 0,5°C
0°C
R/W
-5~5°C, step: 0,5°C
0°C
R/W
-5~5°C, step: 0,5°C
0°C
R/W
0: No
1: Yes
0
1
4
2
1
R/W
18~30°C, step: A.3.2.4
30°C
R/W
12~18°C, step: A.3.2.4
12°C
R/W
25~35°C, step: A.3.2.4
35°C
R/W
15~25°C, step: A.3.2.4
15°C
R/W
0: Disabled
1: Enabled
2: Only DHW
R/W
0: None
1: BSH
2: BUH
R/W
14~35°C, step: 1°C
25°C (*5)
14~35°C, step: 1°C
35°C (*6)
R/W
0: Limited
1: No limit
2: Most optimum
3: Optimum
4: Only legionella
2
0
0/1
R/W
0: No
1: Yes
R/W
0: No limitation
1: Continuous
2: Digital inputs
R/W
0: Current
1: Power
0
R/W
1~10°C, step: 0,5°C
1°C
R/W
1~10°C, step: 0,5°C
3°C
R/W
0: Allowed
1: Not allowed
R/W
-15~35°C, step: 1°C
0°C
R/W
0: Disabled [E-07]≠
1
1: Enabled [E-07]=1
R/W
-15~35°C, step: 1°C
0°C
R/W
0~20°C, step: 1°C
10°C
R/W
0~50 A, step: 1 A
50 A
R/W
0~50 A, step: 1 A
50 A
R/W
0~50 A, step: 1 A
50 A
R/W
0~50 A, step: 1 A
50 A
R/W
0~20 kW, step: 0,5 kW
20 kW
R/W
0~20 kW, step: 0,5 kW
20 kW
R/W
0~20 kW, step: 0,5 kW
20 kW
R/W
0~20 kW, step: 0,5 kW
20 kW
R/W
0: 1P,(1/2)
1: 1P,(1/1+2) (*3)
2: 3P,(1/2)
3: 3P,(1/1+2)
4: 3PN,(1/2)
5: 3PN,(1/1+2) (*4)
1
R/W
2~20°C, step: 1°C
2°C
R/W
0~10°C, step: 1°C
2°C
Installer setting at variance with
default value
Date
Value
(*1) *HB*_(*2) *HV*_
(*3) *3V_(*4) *9W_
(*5) *04/08*_
(*6) *11/16*