Daikin ERLQ004CA Installer's Reference Manual page 65

Daikin altherma - low temperature split
Hide thumbs Also See for ERLQ004CA:
Table of Contents

Advertisement

1
0
1
0
[8-00]
[8-01]
[8-02]
1
Heat pump domestic water heating mode (1=active, 0=not
active)
2
Hot water request for heat pump (1=request, 0=no request)
t
Time
[8-03]: Booster heater delay timer
1
4
0
1
3
0
1
0
1
0
[8-03]
1
Booster heater operation (1=active, 0=not active)
2
Heat pump domestic water heating mode (1=active, 0=not
active)
3
Hot water request for booster heater (1=request, 0=no
request)
4
Hot water request for heat pump (1=request, 0=no request)
t
Time
[8-04]: Additional running time at [4-02]/[F-01]
t
[8-01]+
[8-04]
[8-02]
[8-01]
0
[5-03]
[4-02]
T
T
Ambient (outdoor) temperature
A
t
Time
Anti-recycle time
Maximum running time domestic hot water
Disinfection
Applies only to installations with a domestic hot water tank.
The disinfection function disinfects the domestic hot water tank by
periodically heating the domestic hot water to a specific temperature.
CAUTION
The disinfection function settings MUST be configured by
the installer according to the applicable legislation.
ERLQ004~008CA + EHBH/X04+08CB
Daikin Altherma – Low temperature split
4P384972-1B – 2017.04
t
t
t
[8-01]+
[8-04]
[8-02]
[8-01]
0
[F-01]
35°C
A
#
Code
[A.4.4.2]
[2‑00]
[A.4.4.1]
[2‑01]
[A.4.4.3]
[2‑02]
[A.4.4.4]
[2‑03]
[A.4.4.5]
[2‑04]
T
DHW
[2-03]
T
H
T
U
00.00
01.00
T
Domestic hot water temperature
DHW
T
User set point temperature
U
T
High set point temperature [2-03]
H
t
Time
WARNING
Be aware that the domestic hot water temperature at the
T
hot water tap will be equal to the value selected in field
A
setting [2-03] after a disinfection operation.
When the high domestic hot water temperature can be a
potential risk for human injuries, a mixing valve (field
supply) shall be installed at the hot water outlet connection
of the domestic hot water tank. This mixing valve shall
secure that the hot water temperature at the hot water tap
never rise above a set maximum value. This maximum
allowable hot water temperature shall be selected
according to the applicable legislation.
CAUTION
Be sure that the disinfection function start time [A.4.4.3]
with defined duration [A.4.4.5] is NOT interrupted by
possible domestic hot water demand.
8 Configuration
Description
Operation day:
▪ 0: Each day
▪ 1: Monday
▪ 2: Tuesday
▪ 3: Wednesday
▪ 4: Thursday
▪ 5: Friday
▪ 6: Saturday
▪ 7: Sunday
Disinfection
▪ 0: No
▪ 1: Yes
Start time: 00~23:00, step: 1:00.
Temperature target:
▪ With
booster
heater:
55°C~80°C,
default: 70°C.
▪ Without booster heater: 60°C (fixed).
Duration:
▪ With booster heater: 5~60 minutes,
default: 10 minutes.
▪ Without
booster
heater:
minutes, default: 40 minutes.
[2-04]
22.00
23.00
24.00
t
[2-02]
Installer reference guide
40~60
65

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ehbh/x04Erlq006caErlq008caEhbh/08cb

Table of Contents