E F E R E N C E
Speed potentiometer across A1
(low), B3(high), A4(wiper) OR
External 2-wire speed reference
between A1(-) and A4(+)
Jumper A6 to B3
S
F
P E E D
E E D B A C K
S
E Q U E N C I N G
E-Stop relay n.o. contact between B8, C9
E-Stop relay n.o. TDD contact between B9, C9
Jumper C1 and C2 if no external trip contact
Jumper C5 and C9 for internal enable contact
Start contact between C3 and C9
Jog contact between C4 and C9
Health relay coil (24V) between B6(+) and C1(-)
Armature Voltage is the default speed feedback
mode and does not require a feedback card.
Four feedback cards are available. Analog Tach,
encoder, acrylic microtach and glass microtach.
Select the correct feedback card. Install it on the
feedback header, shown by the arrow in the figure.
Ensure all standoffs are securely snapped in place
On the analog tach card, set switch settings in Units,
Tens and Hundred, corresponding to tachometer
output voltage at maximum speed
DC Analog Tach: G3(+), G4(-). Set switch to DC
AC Analog Tach: G1, G2. Set switch to AC
Encoder: E1=0V, E2=+, E3,E4=A, A, E5,E6=B, B
Microtach: C1=0V, C9=24V, F1=fiberoptic receive
ESCAPE ONE LEVEL
E
SCROLL
SCROLL
DOWN
UP
M
ENTER MENU
The DC590+ can also be calibrated using the programming tool software.
DIGITAL DC DRIVE
This is the power-up welcome screen
DC 4Q 34A
DC 4Q 34A
Press the M key to get to MENU LEVEL
M
MENU LEVEL
MENU LEVEL
Press M. You are in MENU LEVEL, at DIAGNOSTICS
M
DIAGNOSTICS
MENU LEVEL
Up arrow to get to CONFIGURE DRIVE menu
CONFIGURE DRIVE
Press M and up arrow to ENABLE drive configuration
CONFIGURE DRIVE
M
All 7 LEDs blink in Configuration mode. Press E when done
CONFIGURE ENABLE
NOM MOTOR VOLTS
Using the Up & Down arrows, enter rated motor voltage
ARMATURE CURRENT
Enter rated motor armature current
FIELD CURRENT
Enter rated field current. Skip if field is in Voltage mode
FLD. CTRL MODE
Toggle between voltage and current modes
If in voltage mode: Ratio = (field volts/AC supply)*100
FLD. VOLTS RATIO
Example: For a 300V field and 460V supply: Ratio = 300/460*100 = 65%
MAIN CURR.LIMIT
Enter desired current limit setting. Usually 100%
AUTOTUNE
Leave this OFF. Autotune after calibration is complete
SPEED FBK SELECT
Choose from Armature Volts/Analog Tach/Encoder
ENCODER LINES
Enter the pulses per rev. rating of the encoder
ENCODER RPM
Enter the max speed here. Corresponds to 100% speed
ENCODER SIGN
Change the polarity of the encoder signal
SPD. INT TIME
Speed loop integral gain
SPD. PROP GAIN
Speed loop proportional gain
Set CONFIGURE ENABLE to DISABLE. The drive will display "CALIBRATING"
Under MENU LEVEL/PARAMETER SAVE, press the M and UP to save your settings
C
A L I B R AT I O N
All calibration is done in software, through
the keypad.