Trouble Shooting Mass 6000 - Siemens SITRANS F C MASSFLO MASS 6000 Ex-d Manual

Sitrans f c massflo series mass flowmeters signal converter type mass 6000 ex-d sensor type mass 2100 compact or remote mounted
Table of Contents

Advertisement

SITRANS F C MASSFLO
6.2 Trouble shooting
MASS 6000
26
    
6. Service
Symptom
Output
signals
Empty display
Minimum
No flow signal
Minimum
Undefined
Indicates flow
Undefined
with no flow
in pipe
Unstable
Unstable
flow signal
Measuring error
Undefined
Maximum
Loss of totalizer
OK
data
Replacement MASS 6000 or SENSORPROM
Disconnect the equipment from the supply curciuts and wait 30 minuts for discharging the
energy in the internal electronic as before opening.
SFIDK.PS.028.Q1.02
Error
Cause
code
1. Supply voltage
2. MASS 6000 defective
1. Current output deselected
2. Digital output deselected
3. Reverse flow direction
W31
Measuring pipe empty
F60
Internal error
P42
1. No load on current output
2. MASS 6000 defective
P41
Initializing error
Measuring pipe empty
1. Pulsating flow
2. Air bubbles in medium
3. Vibrations
4. Pump noise
Faulty zero-point
P40
No SENSORPROM
F61
Deficient SENSORPROM
unit
F62
Wrong SENSORPROM
unit
F63
Defective SENSORPROM
unit
F80-83 Loss of internal data
W30
Flow exceeds 120% of Q
W21
Pulse overflow
• Mass/pulse too small
• Pulse width too large
W20
Initializing error
    
unit
Remedy
1. Check supply voltage
2. Replace MASS 6000
1. Activate current output
2. Activate digital output
3. Change direction
Ensure that the measuring
pipe is full
Replace MASS 6000
1. Check cables/connections
2. Replace MASS 6000
Switch off MASS 6000,
wait 5 s and switch on again
Select empty pipe limit
Ensure that the measuring
pipe is full of liquid
1. Increase time constant
2. Ensure medium does not
contain air bubbles
3. Ensure that the sensor is
mounted on a rigid frame
without vibrations
4. Ensure that pump frequency
is different from resonance
frequency of sensor
Make new zero-point
adjustment
unit
Install SENSORPROM
Replace SENSORPROM
Replace SENSORPROM
Replace SENSORPROM
Replace MASS 6000
Check Q
(Basic Settings)
max.
max.
Change mass/pulse
Change pulse width
Reset totalizer manually
unit
unit
unit
unit

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sitrans f c massflo mass 2100 di 6Sitrans f c massflo mass 2100 di 3Sitrans f c massflo mass 2100 di 1.5Sitrans f c massflo mass 2100 di 25Sitrans f c massflo mass 2100 di 40

Table of Contents