Connecting Procedure Of Operation Panel With External Vehicle; Media - JUKI IP-310 Setup Manual

Hide thumbs Also See for IP-310:
Table of Contents

Advertisement

%. CONNECTING PROCEDURE OF OPERATION PANEL WITH EXTERNAL VEHICLE

It is possible for this operation panel to perform communication or input of signal with the vehicles below
other than the control box.

. Media

2. RS-232C
3. Input of signal by means of the connector for external input
Connecting procedure is given below.
1. Media
(1) Inserting direction of the media
1. When the inserting direction is wrong, panel or media may be damaged.
2. Do not insert anything other than CompactFlash (TM).
3. IP-310 is adaptable to CompactFlash (TM) of 2GB or less.
4. IP-310 is adaptable to the format FAT16 of CompactFlash (TM). It is not adaptable to
FAT32.
5. Be sure to use the CompactFlash (TM) formatted with IP-310. For formatting proce-
dure of CompactFlash (TM), see
(2) Removing procedure of the media
Media
"%-1-(3) Performing formatting of the media",
1 Hold the panel by hand, open the cover, and press the
media removing lever. The media is eject.
2 When the media is drawn out as it is, removing is com-
pleted.
– 4 –
1 Turn the label side of the CompactFlash (TM)
to this side (place the notch of the edge to
the rear. ) and insert the part that has a small
hole into the panel.
2 After completion of setting of the media, close
the cover. By closing the cover, it is possible
to access. If the media and the cover come in
contact with each other and the cover is not
closed, check the following matters.
• Check that the media is securely pressed
until it goes no further.
• Check that the inserting direction of the media
is proper.
When the lever is strongly pressed, the media
may be broken by protruding and falling.
p.5.