Step 3: Install wall mount bracket to the wall. Use the provided template to locate wall-mounting
holes to ensure hole locations match the bracket. Distance from floor to bottom of wall mount
bracket should be 18" minimum for indoor use and 24" minimum for outdoor use. Distance to the
top of the unit should be 48" maximum for all applications per NEC 625.29. For ADA compliant
installation, refer
to ADA accessibility guidelines, section 4.2
Step 4: Slide WattStation unit onto the mounting bracket, ensuring that the opening in the back
plate bracket aligns with the tab on the wall mount bracket