Table 5.
Zone types (continued)
Zone type
Description
4. Follower with autoby-
This zone is instant when the system is armed
pass disabled
and no entry or exit delays are being timed. It
is delayed 1 time during entry and exit. This
zone does not automatically bypass even if
enabled in segment 1.
5. Interior follower with
This zone is instant when the system is armed
autobypass
and no entry or exit delay is being timed. It is
delayed 1 time during entry and exit. This
zone automatically bypasses if enabled in
segment 1.
6. Instant
This zone creates an instant alarm whenever
it is tripped and the armed LED is on.
7. 24-hour silent
This zone creates an instant silent alarm
regardless of the armed state of the control
panel. It does not display on the keypad.
8. Fire
This zone illuminates the fire LED and sounds
the temporal siren each time the zone is
shorted. The fire LED flashes rapidly indi-
cating a problem if the zone is open.
9. Entry/exit delay 2
A trip starts entry delay 2. The lack of a trip
during exit delay enables the automatic
bypass or instant mode if programmed.
10. 24-hours silent super-
This zone creates an instant silent alarm
vised
regardless of the armed state of the control
panel. It displays on the keypad.
11. Reserved
12. Interior follower with
This zone is instant when the system is armed
cross zone
and no entry or exit delay is being timed. It is
delayed during entry and exit delay times. If a
cross zone is not being timed, it starts a cross
zone timer. If a cross zone is being timed, it
creates an instant alarm. This zone automati-
cally bypasses when enabled in segment 1.
13. Instant entry guard
This zone creates on instant alarm whenever
it is tripped and the stay LED is off. It starts an
entry delay type 2 if it is tripped, the system is
armed, and the stay LED is on.
14. Entry/exit delay 1 with
A trip starts entry delay 1. This zone bypasses
group bypass
when the group bypass command is entered
at the keypad. The lack of a trip during exit
delay enables the automatic bypass or
instant mode if programmed.
15. Interior follower with
This zone is instant when the system is armed
group bypass
and no entry or exit delays are being timed. It
is delayed during entry/exit delay times. This
zone bypasses when the group bypass
command is entered at the keypad. This zone
automatically bypasses if enabled in segment
1.
16. Instant with group
This zone creates an instant alarm whenever
bypass
it is tripped and the armed LED is on. This
zone bypasses when the group bypass
command is entered at the keypad.
17. Entry/exit delay 1 with
A trip starts entry delay 1. The lack of a trip
tamper
during exit delay enables the automatic
bypass or instant mode if programmed. This
zone type is used to enable the tamper on a
wireless transmitter.
18. Interior follower with
This zone is instant when the system is armed
tamper and autobypass
and no entry or exit delay is being timed. It is
delayed during entry and exit delay times.
This zone automatically bypasses if enabled
in segment 1. This zone type is used to enable
the tamper on a wireless transmitter.
19. Instant with tamper
This zone creates an instant alarm whenever
it is tripped and the armed LED is on. This
zone type is used to enable the tamper on a
wireless transmitter.
Table 5.
Zone types (continued)
Zone type
Description
20. Entry/exit delay 2 with
A trip starts entry delay 2. The lack of a trip
tamper
during exit delay enables the automatic
bypass or instant mode if programmed. This
zone type is used to enable the tamper on a
wireless transmitter.
21. Gas detection
This zone creates an instant alarm regardless
of the armed state of the control panel. It
displays on the keypad and activates the
keypad sounder.
22. Low temperature
This zone creates an instant silent alarm
detection
regardless of the armed state of the control
panel. It displays on the keypad and activates
the keypad sounder.
23. High temperature
This zone creates an instant silent alarm
detection
regardless of the armed state of the control
panel. It displays on the keypad and activates
the keypad sounder.
24. Manual fire
This zone illuminates the fire LED and sounds
the temporal siren each time the zone is
shorted. It also flashes (rapidly) the fire LED,
indicating a problem if the zone is open.
25. Chime only
This zone creates no alarm regardless of the
armed state of the control panel. It chimes
anytime it is faulted and displays on the
keypad. Local only.
26. Interior follower delay 2
This zone is instant when the system is armed
and no entry or exit delay is being timed. It is
delayed 2 times during entry and exit. This
zone automatically bypasses if enabled in
segment 1.
27. Interior follower force
This zone is instant when the system is armed
armable
and no entry or exit delay is being timed. It is
delayed 1 time during entry and exit. This
zone automatically bypasses if enabled in
segment 1.
28. Entry/exit force
A trip starts entry delay 2. The lack of a trip
armable delay 2
during exit delay enables the automatic
bypass or instant mode if programmed.
29. Interior follower with
This zone is instant when the system is armed
activity supervision
and no entry or exit delay is being timed. It is
delayed during entry and exit delay times. It
sends a report if the zone activity time is
reached without a change of state. This zone
automatically bypasses if enabled in segment
1.
30. Entry/exit with activity
A trip starts entry delay 1. It sends a report if
supervision
the zone activity time is reached without a
change of state. The lack of a trip during exit
delay enables the automatic bypass or
instant mode if programmed.

Underwriters laboratories information

The NetworX NX-6V2 holds the following listings from Under-
writers Laboratories (US and Canadian):
UL365
Police station connected burglar alarms
UL609, CAN/ULC-S303-M91
Mercantile, police station connect with basic
line security requires NX-003-C enclosure
UL985, CAN/ULC-S545-M89
Household fire
UL1023, ORD-C1023-1974
Household burglary
UL1610
Central station burglar alarm unit
UL1635
Digital alarm communicator system units
UL1637
Home health care signaling
5