GROUP:PROTECTION FUNCTION PARAMETERS (Cont.)
Function / Title
Reg.
143
FAULT TRIP EEPROM SAVE ENABLE
144
COOLING FAN CONTROL SELECTION
145
CUMULATIVE RUN TIMER ALARM SETTING

8.3.8 GROUP:PATTERN RUN CONTROL PARAMETERS

Reg.
Function / Title
146
PATTERN RUN SELECTION
147
1
PATTERN RUN CONTINUE MODE
148
PATTERN GROUP #1 SPEED #0
149
PATTERN GROUP #1 SPEED #1
150
PATTERN GROUP #1 SPEED #2
151
PATTERN GROUP #1 SPEED #3
152
PATTERN GROUP #1 SPEED #4
153
PATTERN GROUP #1 SPEED #5
154
PATTERN GROUP #1 SPEED #6
155
PATTERN GROUP #1 SPEED #7
156
PATTERN GROUP #1 NUMBER OF CYCLES
157
PATTERN GROUP #2 SPEED #0
158
PATTERN GROUP #2 SPEED #1
159
PATTERN GROUP #2 SPEED #2
15A
PATTERN GROUP #2 SPEED #3
15B
PATTERN GROUP #2 SPEED #4
15C
PATTERN GROUP #2 SPEED #5
15D
PATTERN GROUP #2 SPEED #6
15E
PATTERN GROUP #2 SPEED #7
15F
PATTERN GROUP #2 NUMBER OF CYCLES
160
PATTERN GROUP #3 SPEED #0
161
PATTERN GROUP #3 SPEED #1
162
PATTERN GROUP #3 SPEED #2
163
PATTERN GROUP #3 SPEED #3
164
PATTERN GROUP #3 SPEED #4
165
PATTERN GROUP #3 SPEED #5
166
PATTERN GROUP #3 SPEED #6
167
PATTERN GROUP #3 SPEED #7
168
PATTERN GROUP #3 NUMBER OF CYCLES
169
PATTERN GROUP #4 SPEED #0
16A
PATTERN GROUP #4 SPEED #1
16B
PATTERN GROUP #4 SPEED #2
16C
PATTERN GROUP #4 SPEED #3
16D
PATTERN GROUP #4 SPEED #4
16E
PATTERN GROUP #4 SPEED #5
16F
PATTERN GROUP #4 SPEED #6
170
PATTERN GROUP #4 SPEED #7
171
PATTERN GROUP #4 NUMBER OF CYCLES
172
SPEED #1 CONTINUE MODE
Bank
Address
Mask
0 / 1
04B6
0002
0 / 1
04BE
0004
0 / 1
0422
FFFF
Bank
Address
Mask
0 / 1
04A7
0008
0 / 1
04A7
0001
1
0500
00FF
1
0501
00FF
1
0502
00FF
1
0503
00FF
1
0504
00FF
1
0505
00FF
1
0506
00FF
1
0507
00FF
0 / 1
049E
00FF
1
0508
00FF
1
0509
00FF
1
050A
00FF
1
050B
00FF
1
050C
00FF
1
050D
00FF
1
050E
00FF
1
050F
00FF
0 / 1
04A0
00FF
1
0510
00FF
1
0511
00FF
1
0512
00FF
1
0513
00FF
1
0514
00FF
1
0515
00FF
1
0516
00FF
1
0517
00FF
0 / 1
04A2
00FF
1
0518
00FF
1
0519
00FF
1
051A
00FF
1
051B
00FF
1
051C
00FF
1
051D
00FF
1
051E
00FF
1
051F
00FF
0 / 1
04A4
00FF
1
052E
00FF
23
Adjustment Range
0000: Data cleared when
powered OFF
0001: Data retained when
powered OFF
0000: Automatic (temperature
detection)
0001: Always ON
0000 ∼ C34B (0.00 ∼ 999.90)
Adjustment Range
0000: OFF
0001: ON
0000: reset on stop
0001: switch when done
0000: Skip
0001 ∼ 000F: Speeds 1 ∼ 15
0001 ∼ 00FF: 1 ∼ 255
0000: Skip
(0)
0001 ∼ 000F: Speeds 1 ∼ 15
0001 ∼ 00FF: 1 ∼ 255
0000: Skip
(0)
0001 ∼ 000F: Speeds 1 ∼ 15
0001 ∼ 00FF: 1 ∼ 255
0000: Skip
(0)
0001 ∼ 000F: Speeds 1 ∼ 15
0001 ∼ 00FF: 1 ∼ 255
0000: Count in seconds from
time of activation
0001: Count in minutes from
time of activation
0002: Count in seconds from
speed reach
0003: Count in minutes from
speed reach
0004: Non-stop (continue until
STOP command)
0005: Continue until next step
command
Multiplier
0.02
Multiplier
1
1
1
1
1
1
1
1