8.3.6 GROUP:FREQUENCY SETTING PARAMETERS

Reg.
Function / Title
81
FREQUENCY PRIORITY SELECTION #1
82
FREQUENCY PRIORITY SELECTION #2
83
ANALOG INPUT FILTER
84
RR TERMINAL STANDARD OR ADJUSTABLE
85
1
RR REFERENCE SETTING POINT #1
86
RR REF POINT #1 FREQUENCY
87
RR REFERENCE SETTING POINT #2
88
RR REF POINT #2 FREQUENCY
89
IV TERMINAL STANDARD OR ADJUSTABLE
8A
1
IV REFERENCE SETTING POINT #1
8B
IV REF POINT #1 FREQUENCY
8C
IV REFERENCE SETTING POINT #2
8D
IV REF POINT #2 FREQUENCY
8E
RX TERMINAL STANDARD OR ADJUSTABLE
8F
1
RX REFERENCE SETTING POINT #1
90
RX REF POINT #1 FREQUENCY
91
RX REFERENCE SETTING POINT #2
92
RX REF POINT #2 FREQUENCY
93
PG TERMINAL STANDARD OR ADJUSTABLE
94
1
PG REFERENCE SETTING POINT #1
95
PG REF POINT #1 FREQUENCY
96
PG REFERENCE SETTING POINT #2
97
PG REF POINT #2 FREQUENCY
98
BINARY INPUT STD OR ADJUSTABLE
99
1
BINARY REF SETTING POINT #1
9A
BINARY REF POINT #1 FREQUENCY
9B
BINARY REF SETTING POINT #2
9C
BINARY REF POINT #2 FREQUENCY
9D
JOG RUN FREQUENCY
9E
Other
JOG STOP METHOD
than 0
9F
PRESET SPEED SELECTION
100
Other
PRESET SPEED MODE ACTIVATION
than 0
101
PRESET SPEED #1 FREQUENCY
102
PRESET SPEED #1 OPERATING MODE
103
2 or
PRESET SPEED #2 FREQUENCY
104
higher
PRESET SPEED #2 OPERATING MODE
Bank
Address
Mask
0 / 1
04BA
0007
0 / 1
04BA
0038
0 / 1
04BC
0003
0 / 1
04B8
0002
0 / 1
0449
00FF
0 / 1
03DA
FFFF
0 / 1
044A
00FF
0 / 1
03DC
FFFF
0 / 1
04B8
0004
0 / 1
044B
00FF
0 / 1
03DE
FFFF
0 / 1
044C
00FF
0 / 1
03E0
FFFF
0 / 1
04B8
0008
0 / 1
044D
00FF
0 / 1
03E2
FFFF
0 / 1
044E
00FF
0 / 1
03E4
FFFF
0 / 1
04B8
0010
0 / 1
044F
00FF
0 / 1
03E6
FFFF
0 / 1
0450
00FF
0 / 1
03E8
FFFF
0 / 1
04B8
0001
0 / 1
0447
00FF
0 / 1
03D6
FFFF
0 / 1
0448
00FF
0 / 1
03D8
FFFF
0 / 1
03EA
FFFF
0 / 1
04B6
00C0
0 / 1
04A6
000F
0 / 1
04BB
0004
1
0528
FFFF
1
052A
040C
1
0530
FFFF
1
0532
040C
20
Adjustment Range
0001: RR (1)
0002: IV (2)
0003: RX (3)
0004: PG (4)
0005: BIN(5)
0001: RR (1)
0002: IV (2)
0003: RX (3)
0004: PG (4)
0005: IN (5)
0000: No filter
(0)
0001: Small filter
(1)
0002: Medium filter (2)
0003: Large filter
(3)
0000: Standard
(0)
0001: Adjustable
(1)
0000 ∼ 0064 (0 ∼ 100)
0000 ∼ Fmax
0000 ∼ 0064 (0 ∼ 100)
0000 ∼ Fmax
0000: Standard
(0)
0001: Adjustable
(1)
0000 ∼ 0064 (0 ∼ 100)
0000 ∼ Fmax
0000 ∼ 0064 (0 ∼ 100)
0000 ∼ Fmax
0000: Standard
(0)
0001: Adjustable
(1)
009C ∼ 00FF, 0000 ∼ 0064
(-100 ∼ -1, 0 ∼ 100)
-Fmax ∼ Fmax
009C ∼ 00FF, 0000 ∼ 0064
(-100 ∼ -1, 0 ∼ 100)
-Fmax ∼ Fmax
0000: Standard
(0)
0001: Adjustable
(1)
009C ∼ 00FF, 0000 ∼ 0064
(-100 ∼ -1, 0 ∼ 100)
-Fmax ∼ Fmax
009C ∼ 00FF, 0000 ∼ 0064
(-100 ∼ -1, 0 ∼ 100)
-Fmax ∼ Fmax
0000: Standard
(0)
0001: Adjustable
(1)
0000 ∼ 0064 (0 ∼ 100)
-Fmax ∼ Fmax
0000 ∼ 0064 (0 ∼ 100)
-Fmax ∼ Fmax
0000 ∼ 07D0 (0.00 ∼ 20.00)
0000: Decelerated stop (0)
0001: Coast stop
(1)
0002: DC injection stop (2)
0000 ∼ 000F (0 ∼ 15)
0000: Deactivated (0)
0004: Activated
(1)
LL ∼ UL
0000
(0)
0001
(1)
0002
(2)
0003
(3)
0004
(4)
0005
(5)
0006
(6)
0007
(7)
LL ∼ UL
(Note 1)
Multiplier
1
0.01
1
0.01
1
0.01
1
0.01
1
0.02
1
0.02
1
0.02
1
0.02
1
0.02
1
0.02
0.01
1
0.01
1
0.01
1

Hide quick links: