RDA-7
RDA-7 Primary Connections For Different Voltages
AC Board Jumpers
For voltages in the 100V - 120V range, install the two jumpers marked L
For voltages in the 200V - 240V range install the single jumper marked H
Main Transformer Jumpers
The following connections should be made for different line voltages:
100V:
K1-3 to BL1-4,
P7 to BL1-3
P2 to BL1-2
K2-3 to BL1-12,
P8 to BL1-11
P3 to BL1-10
110V:
K1-3 to BL1-6,
P7 to BL1-5
P2 to BL1-2
K2-3 to BL1-14,
P8 to BL1-13
P3 to BL1-10
120V:
K1-3 to BL1-8,
P7 to BL1-7
P2 to BL1-2
K2-3 to BL1-16,
P8 to BL1-15
P3 to BL1-10
200V:
K1-3 to BL1-4
BL1-2 to BL1-3
K2-3 to BL1-12
BL1-10 to BL1-11
220V:
K1-3 to BL1-6
BL1-2 to BL1-5
K2-3 to BL1-14
BL1-10 to BL1-13
230V:
K1-3 to BL1-6
BL1-2 to BL1-7
K2-3 to BL1-14
BL1-10 to BL1-15
240V:
K1-3 to BL1-8
BL1-2 to BL1-7
K2-3 to BL1-16
BL1-10 to BL1-15