Available languages

Product Information / Produktinformation A6312
Rotational Speed Monitor
Function outputs
Opto − decoupled collector / emitter lines
Out 1−1 C / Out 1−1 E
Out 1−2 C / Out 1−2 E
Out 2−1 C / Out 2−1 E
Out 2−2 C / Out 2−2 E
Maximum values for alarm outputs
active state of function outputs
Open circuit / closed circuit mode
Selectable by means of external signal inversion at binary inputs d24 and z24, only for the
function outputs Out 1−1 and Out 2−1.
Outputs Out 1−2 and Out 2−2 are invariably fixed to open circuit mode
Switch over Out 1−1
Switch over Out 2−1
Switching level
Input resistance

1.6.4 Communication interfaces

RS 232 interface
Front socket for connecting a laptop / computer for configuration and visualization purposes
Round plug connector
on the front side
RS 485 interface
d4, z4 bus interface for communication with an MMS 68xx epro analysis and diagnostic
system and the configuration software.
d26 (collektor) / d28 (emitter)
b26 (collektor) / b28 (emitter)
d30 (collektor) / d32 (emitter)
b30 (collektor) / b32 (emitter)
C−E off:
max. voltage U
C−E conducting: max. current I
conducting in the open circuit mode
switched of in the closed circuit mode
d24 = HIGH / open → open circuit mode
d24 = LOW → closed circuit mode
z24 = HIGH / open → open circuit mode
z24 = LOW → closed circuit mode
LOW: 0 ... +3 V
HIGH: 13 ... 48 V
>10 kΩ
Mini
DIN
socket
parameterization cable (included in the operating kit)
Page 16
= 48 V
CE
= 100 mA
CE
type
TM
0508A/6