8.11 Replacing the Condenser
NOTE: Before replacing any component of the refrigeration system, make sure to read the
instructions "Service Precautions for R600A System".
1. Disconnect the unit from its power source.
2. Remove all R600a from the unit in a well ventilated area.
3. Lay the unit on its back and remove the screws
4. Loosen/remove the base plates
5. Clean and then desolder the inlet and the outlet tube from the old condenser
6. Install the new condenser to the cabinet by the screws.
7. Clean then connect the hot pipe to the outlet tubing. Clean and connect the inlet tubing of the
condenser to the spiral pipe.
8. Solder all joints. Silver solder and proper flux should be used on copper to steel or steel to
steel joints. Excess flux should be wiped off all tubing.
○
2 which secure the condenser to the cabinet.
○
○
3 to gain better access to the condenser if needed.
1 and
○
4 .