Electric Heated Dryers
Electrical Specifications (50Hz) – Gas and Steam Models
AD-115ES
220V 3~
230V 3~
25
240V 3~
380-400V 3~
15
416V 3~
15
440V 3~
Electrical Specifications (50Hz) – Electric Models
AD-115ES
Oven
(kW)
Amps
Breaker
380V 3~
50.5
86
125
440V 3~
50.5
75
125
230V 3~
55
155
200
400V 3~
55
88
125
416V 3~
60
93
125
380V 3~
60.5
101
150
440V 3~
60.5
88
150
230V 3~
66
182
250
400V 3~
66
104
150
416V 3~
72
109
150
380V 3~
105
---
---
400V 3~
116
---
---
416V 3~
126
---
---
Gas Information _________________
Gas installation should be performed by qualified
personnel in accordance with national and local
safety regulations.
Before installation, check that the local distribution conditions,
nature of gas and pressure, and the adjustment of the
appliances are compatible.
113579 -1
AD-120ES
AD-170
---
---
40
25
40
---
25
---
15
30
15
20
---
15
---
AD-120ES
AD-170
Amps
Breaker
Amps
Breaker
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
101
150
---
---
---
---
184
250
---
104
150
---
109
150
---
---
---
176
---
---
184
---
---
191
www.adclaundry.com
This appliance must only be installed in the country that is
indicated on the rating plate (data badge). If the appliance is to
be installed in a country other than the one indicated, a new
rating plate must be obtained from the manufacturer.
Refer to the Technical Specifications section for minimum gas
supply pipe size (do not reduce). Piping should conform to local
and national requirements. In AU/NZ, refer to AS/NZS 5601.1
for guidance on gas supply pipe size for this appliance
installation.
If the gas connection is made with a flexible hose, it must be
suitable for the appliance category in accordance with national
safety regulations of the country of destination.
Mount a shutoff valve upstream from the dryer.
Test all connections for leaks.
The burner will attempt to light for maximum of 8-seconds (2
retries).
The dryer must be restrained to prevent straining the gas supply
connection (fastening holes are provided in the top of the dryer
for this purpose). The length and design of the restraint should
be suitable to prevent strain on the gas line if the dryer is moved.
If the dryer is to be moved then the following steps must be
taken:
• Disconnect electrical power to the dryer.
• Close all external gas supply shutoff valves.
• Disconnect the gas supply line.
• Remove the restraint from the dryer.
I
(8)
1ab
---
---
I
(20)
---
2H
---
I
(20)
---
2E
---
I
(20/25)
2E+
---
I
(20/25)
---
2Er
---
I
(25)
2L
---
250
250
I
(28-30/37)
3+
250
I
(37)
3P
I
(30)
3B/P
I
(50)
3B/P
AU / NZ Approved Gas Types
NG
Approved Gas Types
1
st
Family
DK, SE
2
nd
Family
AT, BG, CH, CZ, DK, EE, ES, FI,
GB, GR, HR, IE, IT, LT, LV, NO, PT,
RO, SE, SI, SK, TR
DE, LU, PL
BE
FR
NL
rd
3
Family
BE, CH, CY , CZ, EE, ES, FR, GB,
GR, IE, IT, LT, PT, LV, SK
CZ, PL, SI, SK, TR
CZ, CY , DK, EE, FI, HU, IS, LT, LV,
MT, NL, NO, SE, SI, SK, TR
AT, DE, NL, HU
LPG
9
Need help?