Installation Procedures __________________
Location Requirements
The temperature of the installation location must remain
between 4° C and 55° C.
The dryer must not be installed or stored in an area where it
will be exposed to water and/or weather.
The dryer should be located where a minimum amount of
exhaust ducting will be necessary.
The dryer must be installed on a sound level floor capable of
supporting its weight. Any carpeting must be removed.
Install a lockable door to prevent the public from accessing the
rear of the dryer.
The appliance must not be installed behind a lockable door, a
sliding door or a door with a hinge on the opposite side to that
of the tumble dryer, in such a way that a full opening of the
tumble dryer door is restricted.
Unpacking / Setting Up
Dryer must be handled in an upright position at all times.
Remove protective shipping material (i.e. plastic wrap and
optional shipping box) from the dryer.
Remove the pallet. Remove the 4 bolts securing the base of
the dryer to the pallet (one in each corner of the cabinet base).
Remove the back guard for access to the 2 rear bolts. Remove
the lint door or drawer to reach the 2 front bolts.
If the dryer is to be slid into its final position, ensure that all four
leveling legs (one in each corner) are extended slightly so the
dryer will slide on these legs (not the cabinet frame).
Leveling Dryer
To level dryer, place 10.16 cm
square metal shims (refer to the
illustration on the right) or other
suitable material under the
base pads. It is suggested that
the dryer be tilted slightly to the
rear.
If more headroom is needed
when moving dryer into
position, the top console
(module) may be removed.
Use the following instructions to
remove the top console
(module).
Disconnect the ground wire (A)
at the rear upper left hand
corner of dryer.
Remove the eight sets of nuts and washers (B) holding the
console (module) to base.
Open the control door/control panel and disconnect the white
15-pin plug connector (C) (refer to the illustration below) located
in the base of the control box.
Disconnect white plug connector located outside back side of
the control box (provides power to heat circuit).
Lift the console (module) off the dryer base.
6
Exhaust Transition Piece
Inside the tumbler of this dryer is
an exhaust transition piece that
must be installed on the outlet of
the exhaust before any further
venting is connected:
Remove the exhaust transition
piece from the tumbler and place
it on the exhaust outlet.
Using the screws provided,
secure the exhaust transition
piece to the dryer.
NOTE: It is recommended that
this joint be taped as well as all
other duct joints to prevent
moisture and lint from escaping
into the building.
Dryer Enclosure Requirements
Clearance to combustible material
A
Minimum 30 cm (46 cm recommended)
B
Minimum 92 cm
C
Minimum 5 cm
D
Minimum 10 cm
E
Maximum 10 cm
American Dryer Corp.
113579 -1
Need help?
Do you have a question about the AD-115ES and is the answer not in the manual?