Dell iDRAC7 User Manual page 252

Table of Contents

Advertisement

To assess the capacity of a rack to add additional servers:
1.
View the current power consumption data and historical power consumption data for the servers.
2.
Based on the data, power infrastructure and cooling system limitations, enable the power cap policy and set the
power cap values.
NOTE: It is recommended that you set a cap close to the peak, and then use that capped level to determine
how much capacity is remaining in the rack for adding more servers.
Installing New Electronic License
See
License Operations
for more information.
Applying I/O Identity Configuration Settings for Multiple Network
Cards in Single Host System Reboot
If you have multiple network cards in a server that is part of a Storage Area Network (SAN) environment and you want to
apply different virtual addresses, initiator and target configuration settings to those cards, use the I/O Identity
Optimization feature to reduce the time in configuring the settings. To do this:
1.
Make sure that BIOS, iDRAC, and the network cards are updated to the latest firmware version.
2.
Enable IO Identity Optimization.
3.
Export the XML configuration file from iDRAC.
4.
Edit the I/O Identity optimization settings in the XML file.
5.
Import the XML configuration file to iDRAC.
Related Links
Updating Device Firmware
Enabling or Disabling I/O Identity Optimization
252

Advertisement

Table of Contents
loading

Table of Contents