Atlas Copco GX 7 Instruction Book page 64

Table of Contents

Advertisement

Oil filler plug
Drain valve, air receiver
Attention
62
GX 7 and GX 11
GX 7 and GX 11
Use only authorised parts. Any damage or malfunction caused by the use of unauthorised
parts is not covered by Warranty or Product Liability.
Apply all relevant
Safety
Before carrying out any maintenance or repair work on the compressor: push the stop
button (2).
Wait until the compressor has stopped and switch off the voltage. See the
section.
Open the isolating switch to prevent an accidental start.
Close air outlet valve (2) and depressurise the compressor by opening the oil filler plug (3)
one turn.
Open manual condensate drain valves (4 and/or 5).
The air outlet valve (2) can be locked during maintenance or repair as follows:
• Close the valve.
• Remove the screw fixing the handle
• Remove the handle.
• Fit the screw.