Assembly - YASKAWA V1000 Technical Manual

Hide thumbs Also See for V1000:
Table of Contents

Advertisement

No.
(Addr.
Name
Hex)
F6-55
(3C6)
Baud rate from Network
<6>
F6-56
Speed Scaling
(3D7)
F6-57
Current Scaling
(3D8)
F6-58
Torque Scaling
(3D9)
F6-59
Power Scaling
(3DA)
F6-60
Voltage Scaling
(3DB)
F6-61
Time Scaling
(3DC)
F6-62
Heart Beat
(3DD)
F6-63
(3DE)
MAC ID from Network
<6>
F6-64
Dynamic Output Assembly 109
(3DF)
Programmable Output 1 (DOA109 1)
<9>
F6-65
Dynamic Output Assembly 109
(3E0)
Programmable Output 2 (DOA109 2)
<9>
F6-66
Dynamic Output Assembly 109
(3E1)
Programmable Output 3 (DOA109 3)
<9>
F6-67
Dynamic Output Assembly 109
(3E2)
Programmable Output 4 (DOA109 4)
<9>
F6-68
Dynamic Input Assembly 159
(3E3)
Programmable Input 1 (DIA159 1)
<9>
F6-69
Dynamic Input Assembly 159
(3E4)
Programmable Input 2 (DIA159 2)
<9>
F6-70
Dynamic Input Assembly 159
(3E5)
Programmable Input 3 (DIA159 3)
<9>
F6-71
Dynamic Input Assembly 159
(3E6)
Programmable Input 4 (DIA159 4)
<9>
YASKAWA ELECTRIC SIEP C730600 28B V1000 Option SI-N3/V Technical Manual
Description
(Read only)
DeviceNet actual communication speed
0: 125 k bit/s
1: 250 k bit/s
2: 500 k bit/s
Note: Used in the DeviceNet Object
Sets the scaling factor for the Speed Monitor in the DeviceNet
Object Class 2A hex
Note: Used in the AC/DC Drive Object
Sets the scaling factor for the Output Current Monitor in the
DeviceNet Object Class 2A hex
Note: Used in the AC/DC Drive Object
Sets the scaling factor for the Torque Monitor in the DeviceNet
Object Class 2A hex
Note: Used in the AC/DC Drive Object
Sets the scaling factor for the Power Monitor in the DeviceNet
Object Class 2A hex
Note: Used in the AC/DC Drive Object
Sets the scaling factor for the Voltage Monitor in the DeviceNet
Object Class 2A
Note: Used in the AC/DC Drive Object
Sets the scaling factor for the Time Monitor in the DeviceNet
Object Class 2A hex
Note: Used in the AC/DC Drive Object
Sets the heartbeat interval
Note: Used in the Identity Object
(Read only)
Actual MAC address
Note: Used in the DeviceNet Object
The data in configurable output 1 is written to the MEMOBUS/
Modbus address defined by this parameter.
The data in configurable output 2 is written to the MEMOBUS/
Modbus address defined by this parameter.
The data in configurable output 3 is written to the MEMOBUS/
Modbus address defined by this parameter.
The data in configurable output 4 is written to the MEMOBUS/
Modbus address defined by this parameter.
The data in configurable input 1 is read from the MEMOBUS/
Modbus address defined by this parameter.
The data in configurable input 2 is read from the MEMOBUS/
Modbus address defined by this parameter.
The data in configurable input 3 is read from the MEMOBUS/
Modbus address defined by this parameter.
The data in configurable input 4 is read from the MEMOBUS/
Modbus address defined by this parameter.
6 DeviceNet Option Drive Parameters
Default: 0
Range: 0 to 2
Default: 0
Min: -15
Max: 15
Default: 0
Min: -15
Max: 15
Default: 0
Min: -15
Max: 15
Default: 0
Min: -15
Max: 15
Default: 0
Min: -15
Max: 15
Default: 0
Min: -15
Max: 15
Default: 0
Min: 0
Max: 10
Default: 0
Min: 0
Max: 63
Default: 0x0000
Min: 0x0000
Max: 0xFFFF
Default: 0x0000
Min: 0x0000
Max: 0xFFFF
Default: 0x0000
Min: 0x0000
Max: 0xFFFF
Default: 0x0000
Min: 0x0000
Max: 0xFFFF
Default: 0x0000
Min: 0x0000
Max: 0xFFFF
Default: 0x0000
Min: 0x0000
Max: 0xFFFF
Default: 0x0000
Min: 0x0000
Max: 0xFFFF
Default: 0x0000
Min: 0x0000
Max: 0xFFFF
Values
19