P1001[0] Fixed Frequency 1; P1002[0] Fixed Frequency 2; P1003[0] Fixed Frequency; P1016[0] Fixed Frequency Mode - Siemens Sinamics V20 Operating Instructions Manual

Hide thumbs Also See for Sinamics V20:
Table of Contents

Advertisement

Parameter
Description
13
15
17
20
21
22
23
25
27
P1001[0...2]
Fixed frequency 1 [Hz]
P1002[0...2]
Fixed frequency 2 [Hz]
P1003[0...2]
Fixed frequency 3 [Hz]
P1004[0...2]
Fixed frequency 4 [Hz]
P1005[0...2]
Fixed frequency 5 [Hz]
P1006[0...2]
Fixed frequency 6 [Hz]
P1007[0...2]
Fixed frequency 7 [Hz]
P1008[0...2]
Fixed frequency 8 [Hz]
P1009[0...2]
Fixed frequency 9 [Hz]
P1010[0...2]
Fixed frequency 10 [Hz]
P1011[0...2]
Fixed frequency 11 [Hz]
P1012[0...2]
Fixed frequency 12 [Hz]
P1013[0...2]
Fixed frequency 13 [Hz]
P1014[0...2]
Fixed frequency 14 [Hz]
P1015[0...2]
Fixed frequency 15 [Hz]
P1016[0...2]
Fixed frequency mode
1
2
P1031[0...2]
MOP mode
P1032
Inhibit reverse direction of MOP
0
1
P1040[0...2]
Setpoint of the MOP [Hz]
P1047[0...2]
MOP ramp-up time of the RFG [s]
P1048[0...2]
MOP ramp-down time of the RFG [s]
r1050
CO: Actual output freq. of the MOP [Hz]
P1058[0...2]
JOG frequency [Hz]
P1059[0...2]
JOG frequency left [Hz]
P1060[0...2]
JOG ramp-up time [s]
P1061[0...2]
JOG ramp-down time [s]
P1080[0...2]
Minimum frequency [Hz]
P1082[0...2]
Maximum frequency [Hz]
P1120[0...2]
Ramp-up time [s]
P1121[0...2]
Ramp-down time [s]
P1130[0...2]
Ramp-up initial rounding time [s]
P1131[0...2]
Ramp-up final rounding time [s]
P1132[0...2]
Ramp-down initial rounding time [s]
P1133[0...2]
Ramp-down final rounding time [s]
P1134[0...2]
Rounding type
0
1
P1135[0...2]
OFF3 ramp-down time [s]
P1200
Flying start
0
1
2
20
Fixed frequency + MOP setpoint
USS on RS485 + MOP setpoint
Analog setpoint 2 + MOP setpoint
No main setpoint + Analog setpoint
MOP setpoint + Analog setpoint
Analog setpoint + Analog setpoint
Fixed frequency + Analog setpoint
USS on RS485 + Analog setpoint
Analog setpoint 2 + Analog setpoint
Direct selection
Binary selection
Reverse direction is allowed
Reverse direction inhibited
Continuous smoothing
Discontinuous smoothing
Flying start disabled
Flying start always active; searches in both directions
Flying start active after power on, fault, OFF2; searches in both directions
Range
Factory default
53
Fixed frequency + USS on RS485
55
USS on RS485 + USS on RS485
57
Analog setpoint 2 + USS on RS485
70
No main setpoint + Analog setpoint 2
71
MOP setpoint + Analog setpoint 2
72
Analog setpoint + Analog setpoint 2
73
Fixed frequency + Analog setpoint 2
75
USS on RS485 + Analog setpoint 2
77
Analog setpoint 2 + Analog setpoint 2
-599.00 - 599.00
10.00
-599.00 - 599.00
15.00
-599.00 - 599.00
25.00
-599.00 - 599.00
50.00
-599.00 - 599.00
0.00
-599.00 - 599.00
0.00
-599.00 - 599.00
0.00
-599.00 - 599.00
0.00
-599.00 - 599.00
0.00
-599.00 - 599.00
0.00
-599.00 - 599.00
0.00
-599.00 - 599.00
0.00
-599.00 - 599.00
0.00
-599.00 - 599.00
0.00
-599.00 - 599.00
0.00
1 - 2
1
-
1
0 - 1
1
-599.00 - 599.00
5.00
0.00 - 1000.00
10.00
0.00 - 1000.0
10.00
-
-
0.00 - 599.00
5.00
0.00 - 599.00
5.00
0.00 - 650.00
10.00
0.00 - 650.00
10.00
0.00 - 599.00
0.00
0.00 - 599.00
50.00
0.00 - 650.00
10.00
0.00 - 650.00
10.00
0.00 - 40.00
0.00
0.00 - 40.00
0.00
0.00 - 40.00
0.00
0.00 - 40.00
0.00
0 - 1
0
0.00 - 650.00
5.00
0 - 6
0
Acc. level
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
1
1
1
1
2
2
2
2
2
2
2
Getting Started
A5E31842771, 02/2013