Fusing And Exit; Fusing Unit - Ricoh SP 311DN Service Manual

Hide thumbs Also See for SP 311DN:
Table of Contents

Advertisement

Fusing and Exit

4.7 FUSING AND EXIT
Switch off the main power, unplug the machine from its power source, and allow the
fusing unit to cool before removing it.

4.7.1 FUSING UNIT

1.
Right cover (page 4-8 "Right Cover")
2.
Rear cover (page 4-7 "Rear Cover")
3.
Release the lock [A], and then remove the entrance guide [B] (
4.
Disconnect the three connectors (
5.
Pass the cable [A] through the hole [B] inside the machine.
M154/M155/M174/M175/A0A7/M287/M0BB
x 1)
4-28
x 1)
SM