After Installing A New Fusing Unit; Thermostat - Ricoh SP 311DN Service Manual

Hide thumbs Also See for SP 311DN:
Table of Contents

Advertisement

Fusing and Exit

After installing a new fusing unit

1.
Enter the "Printer Configuration" in SOM.
2.
Select the "SP Mode 3" tab.
3.
Click "Clear Fusing Unit EM Counter" and then click "OK".
4.
Exit the SOM.

4.7.2 THERMOSTAT

Do not recycle a thermoswitch that is already opened. Safety is not guaranteed if you do
this.
1.
Fusing unit (page 4-28 "Fusing Unit")
2.
Fusing upper cover [A] (
3.
Thermostat [A] (
M154/M155/M174/M175/A0A7/M287/M0BB
x 4)
x 2)
4-30
SM