Refrigerant Connections; Connection To The Panel (X1) - Energie ECO 200esm Technical Manual

Table of Contents

Advertisement

Eco

4.4. Refrigerant Connections

The cooling fluid couplings must be
done by a qualified technician, with
a
professional
qualifications for this purpose.
DANGER
The thermodynamic unit holds a
pre-load of fluid R134a.
The cooling fluid couplings must be
thermally insulated in order to
prevent burns and to ensure an
optimal system performance.
DANGER
DIAMETER OF THE PIPES
GAS
(aspiration)
Inches
panels
1
3/8''
2
1/2"
The piping used must be copper without seams of
the refrigeration type (Cu DHP type according to
standard ISO1337)

4.4.1. Connection to the Panel (x1)

a) Prepare the copper pipe, removing the
protective caps from the extremities.
b) Place the extremity of the pipe upside
down, cut the appropriate size of pipe and
sand the rough edge.
c) Remove the females from the couplings in
the panes and insert them in the pipe.
certificate
of
LIQUID
(panel inlet)
Inches
1/4''
3/8"
Technical Manual
c
)
1
)
c
)
2
)
d) Flange the pipe with the appropriate tool
shaping a conic edge, make sure that
there are no rough edges or imperfections
and that the vertical of the walls is
uniform.
WARNING
e) Tighten the female coupling with your
hands, turning it a few times. Then fully
tighten applying a torque in conformity
with the table.
22