PVG 16 and 32 Service Assembly/Disassembly Guide
Assembly instructions
20 |
©
Danfoss | November 2017
For torque tighting values of the large hexagon (Y) with the detent assembly function, please see the
table below.
Tightening torques and widths across flats
With across flats
Tightening torque
PVMR, detent option without a neutral spring
The valve assembly is to be assembled in accordance with the specification sheet.
9. Assemble the shock/check (PVLP) valves into the PVB's. The top of the PVLP valve is marked with the
last three digits of the module code number. This number also indicates the valve pressure setting @
15.1 I/min [4 US gal/min]. Be careful not to swap plugs and valves. The PVLA module carries no
markings. The torque for the plug is 4.0 ± 0.3 N•m [355 ± 25 lbf•in].
X
Y
8 ±0.5 N•m
15 ±2 N•m
[70 ±4.5 lbf•in]
[135 ±20 lbf•in]
PVMF, mechanical float option
Z
4 ±1 N•m
[35 ±9 lbf•in]