Find Faulty Thyristor - ABB DCS800 Service Manual

20 to 5200 a
Hide thumbs Also See for DCS800:
Table of Contents

Advertisement

54
Note:
The Faston connectors of the gates are of different size.
Gate A should always be in front of the clamped heat sinks due to cooling reasons.
Location of BCT's gate A when built in

Find faulty thyristor

1. Find the defective branches by performing an OHM test (both polarities)
between U1, V1, W1 and C1, D1 (see picture
branching fuses
2. Disconnect the branching fuses of the defective branches.
3. Find the defective thyristors by performing an OHM test (both polarities) over
their heat sinks.
4. In a 4 - quadrant converter with BCT's change the BCT.
5. In a 4 - quadrant converter with 2 single thyristors change both thyristors
clamped between the same heatsinks at once.
Note:
Because "Disc Type" semiconductors need a certain compression force to operate
properly, a measurement outside the clamped heat sinks might be wrong. To be
sure which thyristor is broken change only one thyristor, clamp the heat sinks
again and repeat step three.
Exchange of Thyristors for Size D6
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
on page 45).
3ADW000195R0501 DCS800 Service Manual e e