To change the system time:
Press [9] + [Master code] + [0] + [2] + [0].
Enter the current time in 24-hour format, i.e., 1630 for 4:30pm, then press [#].
Press [*] + [0] + [0] + [#] to exit.
Chimes and Beeps
When your system is in chime mode, a chime alert will sound three tones whenever a protected door/window
is opened.
To turn chime mode on and off, press [7] + [1].
Reset
To clear the display after an alarm event, enter the sequence [1] + [security code] twice or enter [1] +
[security code] + [*].

Security Codes

You can program up to 230 users, each with their own level of security.
To add a new user, press [9] + [Master code] + [0] + [3] + [0] + [desired user number, i.e., 27 for user
27].
Enter the desired user 4-digit code + [#].
Press [*] + [0] + [0] + [#] to exit the menu.
To delete a user, press [9] + [Master code] + [0] + [3] + [0].
Enter the user number you wish to delete + [0] + [Master code] + [#].
Press [*] + [0] + [0] + [#] to exit the menu.
New users can be assigned attributes, which define what actions users can and cannot perform. For a
complete list of user attributes, please see the

Trouble Conditions

Trouble conditions are issues that require your attention and are indicated by rapid beeps sounding every
minute until the Trouble Condition is corrected.
To silence the Trouble Condition beeping, press [* Status].