Note: For parameter descriptions, please refer to the associated HART parameters on
pages 27 to 56.
Parameter, menu
identification
4.2.5.A.1: Calibrate
or
4.2.5.A. 1 : Tank design
4.2.5.A.2: Enter table
or
4.2.5.A.2: Bottom
design
4.2.5.A.3: Show table
or
4.2.5.A.3: Tank vol-
ume
4.2.5.A.4: Clear table
or
4.2.5.A.4: Tank height
4.2.6: Mass Parame-
ters
4.2.6.1: Mass URV
4.2.6.2: Mass LRV
4.2.6.3: Mass damp-
ing
4.2.6.4: MinWarn
Mass
4.2.6.5: MinLim mass For qualified personnel only
4.2.6.6: MaxLim mass For qualified personnel only
4.2.6.7: MaxWarn
Mass
4.2.6.8: HYST Mass
4.2.6.9: Tank Charac-
ter
4.2.6.A: Calibrate/table
or
4.2.6.A: Calculate
4.2.6.A.1: Calibrate
or
4.2.6.A. 1 : Tank design
7ML19985JC02
Parameters (PROFIBUS PA)
Description
Automatic litering
Manual entry of a table
Display table
Delete table
= [4.2.1.2]
For qualified personnel only
For qualified personnel only
For qualified personnel only
For qualified personnel only
For qualified personnel only
For qualified personnel only
For qualified personnel only
For qualified personnel only
For qualified personnel only
For qualified personnel only
SITRANS LR 400 (Solids) – INSTRUCTION MANUAL
Factory
Setting
Setting
Possibilities
Confirm input
Vertical cylin-
Linear
der
Vertical cylinder
Horizontal
Cylinder
Sphere
numerical value
Dished end
Dished end
Basket end
Bullet bottom
Selection
numerical value
3
20 m
Selection
Page 65

Advertisement

Table of Contents
loading

Table of Contents