ABB 6X1EH Operating Instructions Manual page 6

600t en series hart pressure transmitters
Hide thumbs Also See for 6X1EH:
Table of Contents

Advertisement

. . . PRINCIPLE OF OPERATION
For the ANALOG version the microprocessor computers the 4
to 20 mA output signal.
For the ANALOG + HART version, in addition to the 4 to 20 mA
output signal, the microprocessor also receives data from the
Primary electronics
(located in the
Primary Unit)
MEMORY
1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8
SENSOR
1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8
INTERFACE
1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8
Sensors
With secondary electronics analog and analog+HART, it is to
be consider that different communication protocols exist for
configuration and maintenance operations. Here follows a
brief description on the matter; please refer to appropriate
technical specification for additional deeper explanations on
the communication aspects.
The HART protocol is based on the standard Bell 202 FSK
(Frequency Shift Keying ) with a ±0.5 mA signal modulation
superimposed on the 4 to 20 mA analog signal. As the energy
balance added to the current loop is virtually zero and the
frequency is very high compared to that of the process dynamic,
the analog process signal remains undisturbed. Using a
configuration device it is then possible to remotely modify the
configuration of the transmitter, e.g. the measuring range.
- 6 -
Zero
EXT. ADJ
INTERFACE
Span
DIGITAL
CONVERTER
Fig. 3 - Functional Block Diagram (Analog + HART version)
internal modem, in order to provide bidirectional digital
communication with the configuration device, i.e. the Hand
Held terminal "Communicator" or P.C. based "Configurator".
MODEM FSK
MEMORY
COUPLER
MICRO
4 to 20 mA
CONTROLLER
CONVERSION
It is also possible to read other transmitter data and diagnostic
information. Limited rezeroing and respanning, comparable to
that conventional analog transmitters is possible using the
optional calibration device. Refer to Fig. 3 for a complete view
of the Functional Block Diagram.
The sensor and all electronic parts are galvanically isolated
from the transmitter body.
For the analog version the Function Block Diagram is the same
as the one represented in Fig. 3, but without the MODEM - FSK
COUPLER box for HART signal generation.
Secondary Electronics
(located in the
Secondary Unit)
Internal bus
Parallel Bus
Internal Serial Bus
4 to 20 mA
Output

Advertisement

Table of Contents
loading

This manual is also suitable for:

6x1ed6x1ee6x1eg6x1es622ed6x1ea

Table of Contents