Sharp SJ-XF50X-T Service Manual page 24

Table of Contents

Advertisement

SJXF50XT
Problem
Self-diagnosis display
R-thermistor fault
R-fan motor fault
Refrigerator
R-thermistor high temperature
compartment (chilled
No self-diagnosis fault
case) is not cooled
well
R-thermistor fault
Refrigerator
compartment (chilled
case)is too much
R-thermistor low temperature
cold.
Ice release operation error
Ice maker thermistor fault
Ice maker thermistor high temperature
Ice making failure
Ice strorage box is full of ice cubes
Ice making speed is
low
No water in water tank
No self-diagnosis fault
Check/inspection point
1) Connector insertion check (Main PWB, intermediate
connector)
2) Thermistor resistance check (Check the value in the
thermistor characteristic table.)
3) If the above check results are normal:
1) Connector insertion check (Main PWB, intermediate
connector)
2) Fan motor installation/condition/operation check
3) If the above check results are normal:
1) R-damper connector insertion check (Main PWB,
intermediate connector)
2) R-damper installation/condition/operation check
3) R-thermistor connector insertion check (Main PWB,
intermediate connector)
4) R-thermistor resistance check (Check the value in the
thermistor characteristic table.)
5) R-fan motor operation check (Rotation speed is low.)
6) Door packing inspection and installation/operating conditions
(Installation environmental temperature, door opening/closing
frequency, too much stuffed food, block of cold air supply port
at the back of the chilled case, suction port, etc.)
7) If the above check results are normal:
1) Connector insertion check (Main PWB, intermediate
connector)
2) Thermistor resistance check (Check the value in the
thermistor characteristic table.)
3) If the above check results are normal:
1) R-damper connector insertion check (Main PWB,
intermediate connector)
2) R-damper installation/condition/operation check
3) If the above check results are normal:
1) Connector insertion check (Main PWB, intermediate
connector)
2) Ice maker ass'y installation/condition/operation check
3) If the above check results are normal:
1) Connector insertion check (Main PWB, intermediate
connector)
2) Thermistor resistance check (Check the value in the
thermistor characteristic table.)
3) If the above check results are normal:
1) Connector insertion check (Main PWB, intermediate
connector)
2) Thermistor resistance check (Check the value in the
thermistor characteristic table.)
3) Door packing inspection and installation/operating condition
check
4) If the above check results are normal:
1) Ice sensor operation check (Check for contact with the ice
storage box, etc.)
2) Ice maker ass y installation/condition/operation check
3) If the above check results are normal:
1) Water tank water level and installation check
2) Water pump connector insertion check (Main PWB,
intermediate connector)
3) Water pump installation/condition/operation check
4) Water pipe installation/condition check
5) Ice maker thermistor resistance check (Check the value in
the thermistor characteristic table.)
6) If the above check results are normal:
1) Ice maker ass'y and water pump operation check in ice tray
cleaning operation
2) Water pipe heater resistance check (approx. 3.5 k)
3) Water pump/pipe installation/condition/operation check
4) If the above check results are normal:
24
Action on error detection
1) Correct the installation.
2) Replace the thermistor.
3) Replace the main PWB.
1) Correct the installation.
2) Correct the installation, or replace the fan motor.
3) Replace the main PWB.
1) Correct the installation.
2) Correct the installation, or replace the R-damper.
3) Correct the installation.
4) Replace the thermistor.
5) Replace the R-fan motor.
6) Improve the packing mounting/installation/operating
condition.
7) Replace the main PWB.
1) Correct the installation.
2) Replace the thermistor.
3) Replace the main PWB.
1) Correct the installation.
2) Correct the installation, or replace the R-damper.
3) Replace the main PWB.
1) Correct the installation.
2) Correct the installation, or replace the ice maker ass'y.
3) Replace the main PWB
1) Correct the installation.
2) Replace the thermistor.
3) Replace the main PWB.
1) Correct the installation.
2) Replace the thermistor.
3) Improve the mounting/installation/operating condition.
4) Replace the main PWB.
1) Correct or replace the ice sensor.
2) Correct the installation, or replace the ice maker ass'y.
3) Replace the main PWB.
1) Replenish water into the water tank. Correct the
installation.
2) Correct the installation.
3) Correct the installation, or replace the water pump.
4) Correct the installation.
5) Replace the thermistor.
6) Replace the main PWB.
1) Replace the ice maker ass'y or water pump.
2) Correct the connector installation, or replace the water
pipe heater.
3) Correct the installation, or replace the water pump/pipe.
4) Replace the main PWB.