Refrigeration Cycle System Specifications; R600A Precautions; Table Of R600A Characteristics; Refrigeration Cycle Diagram - Sharp SJ-XF50X-T Service Manual

Table of Contents

Advertisement

[6] REFRIGERATION CYCLE SYSTEM SPECIFICATIONS

1.

R600A PRECAUTIONS

• Do not use any refrigerant other than R600a.
• Gas leak testers for HFC-134a, CFC-12, HCFC-22, etc., cannot be used.
• A special tool is used for the R600a cycle.
2.

TABLE OF R600A CHARACTERISTICS

Refrigerant saturated vapor pressure table R600a
(Unit) Temperature: °C, Pressure: kgf/cm abs
Temperature
-20
-15
0.91
Pressure
0.74
(Unit)Temperature:°C, Pressure: MPa abs
Temperature
-20
-15
Pressure
0.073
0.089
3.

REFRIGERATION CYCLE DIAGRAM

3-1.
Piping Diagram
←(①~⑱) Show the order of the refrigerant flow
Side condenser L
Bottom condenser
Dew proofing condenser
-10
-5
0
5
1.11
1.34
1.60
1.91
-10
-5
0
5
0.109
0.131
0.157
0.187
Charge pipe
10
15
20
2.25
2.64
3.08
10
15
20
25
0.221
0.259
0.302
0.351
Dryer
Capillary
tube A
Extension
barrel
Charge pipe
Extra
cond.
unit
ass'y
15
25
30
35
40
3.58
4.13
4.74
5.42
30
35
40
45
0.405
0.465
0.532
0.605
Evaporator
Capillary
tube B
Suction
pipe
Suction
connector
Compressor
Discharge pipe
ass'y
Side condenser R
SJXF50XT
45
50
6.17
7.00
50
0.686
Back
condenser

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents