Download Print this page

Keysight Technologies E4990A Configuration Manual page 5

Impedance analyzer 20 hz to 10/20/30/50/120 mhz
Hide thumbs Also See for E4990A:

Advertisement

05 | Keysight | E4990A Impedance Analyzer - Configuration Guide
Available Accessories — General/Miscellaneous Measurement Accessories
(continued)
Description
Model no.
SMD test fixture
16047A
16047A-701
16047E
16047E-ABA
16047E-ABJ
Tweezers test fixture
16334A
Kelvin clip leads
16089A
16089A-800
16089A-C20
16089B
16089B-800
16089B-C20
Kelvin IC clip leads
16089C
External voltage bias
16065A
fixture
Dielectric test fixture
16451B
16451B-ABA
16451B-ABJ
Liquid test fixture
16452A
Test leads
16452-61601
100 Ω resistor
E4990-61001
Note: For more detailed information, refer to Accessories Selection Guide for Impedance Measurements.
Requires
Additional information
(Instrument must
already include
the following)
None
For axial or radial lead device. DC – 13 MHz. Operation and service manual is furnished.
None
Adds Shorting plate
None
For axial or radial lead device. DC – 120 MHz.
None
U.S. – English localization
None
Japan – Japanese localization
None
For SMD; ≤ 10 mm L. Tweezers type; cable length 1 m. DC – 15 MHz. Shorting block
and Operation and Service Manual are furnished.
None
2 large clips. 5 Hz – 100 kHz. Choose mandatory option 16089A-800 or C20.
Operation and service manual is furnished.
None
Cable length: 1 m (standard)
None
Cable length: 2 m
None
2 medium clips. 5 Hz – 100 kHz. Choose mandatory option 16089B-800 or C20.
Operation and service manual is furnished.
None
Cable length: 1 m (standard)
None
Cable length: 2 m
None
2 IC clips; cable length 1 m. 5 Hz – 100 kHz. Operation and service manual is furnished.
None
± 200 V dc max., for axial or radial lead device.
50 Hz – 2 MHz. Shorting plate and Operation and Service Manual are furnished.
None
Test fixture for measuring permittivity of dry solid sheet material; Cable length 1 m.
DC – 30 MHz. 38 mm and 5 mm diameter electrodes for measuring bare material
and two types of electrodes for measuring material with pre-formed electrodes are
furnished.
None
U.S. – English localization
None
Japan – Japanese localization
None
Test fixture for measuring permittivity of liquid material. 20 Hz – 30 MHz. Required
(16048G and four of
volume of material; 3.4, 3.8, 4.8 or 6.8 ml. Temperature range: –20 ° to +125 °C.
1250-0216 BNC(m)
Shorting plate, spacers, SMA-BNC adapters, fixture stand, carrying case and
to BNC(m) adapters)
operation and service manual are furnished.
None
Heat-proof test leads for use with the 16452A. Temperature range: –20 ° to +125 °C
None
100 Ω load resistor module for 4-terminal pair extension. Furnished with the E4990A.