The hot tank requires removal of mineral deposits (descaling) on a regular basis.  Typically 
descaling should take place every 6 to 12 months to preserve the long‐term health of your unit.  
 
Use non‐toxic cleaner such as ScaleKleen, DEZCAL, 20% Citric Acid Solution, or Undiluted Vinegar 
Solution to remove mineral deposits as directed by the manufacturer depending upon filtration 
and local water conditions.   
 
Descaling is an important process that removes calcium deposits, or scale, that can build up 
inside a tank over time.  Calcium and scale is non‐toxic but left unattended will hinder your unit's 
performance.  
 
 
WARNING!  PERSONAL PROTECTIVE EQUIPMENT REQUIRED.  Always ensure proper 
ventilation and use rubber or nitrile gloves and eye protection when using chemicals.  Refer to 
Material Safety Data Sheet for specific requirements of each product.     
 
             CAUTION!   STAINLESS STEEL TANK DESCALING
The hot tank is made from stainless steel.  Ensure descaling solution is compatible with stainless 
and always flush the unit completely.  Dispose in an environmentally safe manner. 
 
Materials Needed:  
 Personal Protective Equipment.  Rubber or Nitrile Safety Gloves and Protective Eyewear  
 Phillips Screwdriver   
 Temperature Gauge 
 Water Pitcher or Container to collect water from the faucet 
 5‐gallon container or drain basin 
 Citric Acid Based Cleaner 
 ¼" Plastic Tubing, at least 4 feet in length, and assorted ¼" quick connect fittings 
 Sanitizing Cartridge 
 Food Coloring 
 
1. Put descaler per directions and 3 drops of food coloring into the descaling cartridge. 
 
2. Connect descaling cartridge to the inlet water supply and connect to inlet bulkhead fitting on the 
back of the unit.  Turn on Water Supply. 
 
3. Select Hot Water and depress the Main Dispensing Button on the Front Control Panel until 
descaling solution (colored water) comes out of the faucet.  Container and drain basin will be 
required to catch water from the faucet. 
 
4. Turn off water supply and remove sanitizing cartridge from inlet water supply.  Reconnect water 
supply to inlet fitting. 
 
 