Welding Problems - Red-D-Arc DC-600 Operator's Manual

Table of Contents

Advertisement

E-10
TROUBLESHOOTING GUIDE
PROBLEMS
(SYMPTOMS)
Poor arc starting when the DC600
is in the CV Sub-Arc or CV
Innershield Modes.
Machine has output but trips off
immediately when wire feed unit
trigger is activated
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
TROUBLESHOOTING
POSSIBLE AREAS OF
MISADJUSTMENT(S)

WELDING PROBLEMS

1. Make sure the proper welding
procedures are being used.
(wire feed speed , arc voltage
and wire size)
2. Check weld cables for loose or
faulty connections.
1. Remove output cables from
DC-600. If problem is resolved
check for external short
between weldiong cables. Also
check control cable (#75, #76,
& #77) for grounds or shorts.
CAUTION
DC-600
Observe Safety Guidelines
detailed in the beginning of this manual.
RECOMMENDED
COURSE OF ACTION
If all recommended possible areas
of misadjustment have been
checked and the problem persists,
Contact your local Authorized
Field Service Facility.
E-10

Advertisement

Table of Contents
loading

Table of Contents